Blood collection and transfusion in the United States in 2001.

Transfusion

National Blood Data Resource Center, and the Department of Transfusion Medicine, National Institutes of Health, Bethesda, Maryland, USA.

Published: March 2007

Background: Collection, processing, and transfusion of blood and blood components in the United States in 2001 were measured and compared with prior years.

Study Design And Methods: The survey was completed by 1443 blood centers and hospitals. Statistical procedures were used to verify the representativeness of the sample and to estimate national totals.

Results: The total US blood supply in 2001 was 15,320,000 units (before testing), 10.4 percent greater than in 1999. It included 14,259,000 allogeneic units, 619,000 autologous units, and 273,000 red cell (RBC) units collected by apheresis. Transfusion of whole blood (WB) and RBCs increased by 12.2 percent to 13,898,000 units. Platelet (PLT) transfusions totaled 10,196,000 units, an increase of 12.6 percent in comparison with 1999. The use of single-donor apheresis PLTs increased by 26.0 percent to 7,582,000 PLT concentrate equivalent units. The use of PLTs from WB (PLT concentrates) continued a downtrend, declining 13.9 percent to 2,614,000.

Conclusions: The margin between transfusion demand and the total allogeneic supply in 2001 was 1,162,000 units, 7.9 percent of supply. By comparison, the 1999 margin was 9.1 percent. The rate of blood collection per 1,000 donor-eligible population in 2001 was 8.9 percent higher than in 1999, due largely to additional donations following the September terrorist attacks. During the same period, however, the rate of transfusion per 1,000 total US population increased by 9.9 percent to 50.0 units, the highest in 15 years of measurement. The steady increase in demand continues to challenge the US blood community.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1537-2995.2007.01128.xDOI Listing

Publication Analysis

Top Keywords

units
9
percent
9
blood
8
blood collection
8
united states
8
states 2001
8
transfusion blood
8
supply 2001
8
comparison 1999
8
transfusion
5

Similar Publications

Validity of one-time phantomless patient-specific quality assurance in proton therapy with regard to the reproducibility of beam delivery.

Med Phys

January 2025

OncoRay - National Center for Radiation Research in Oncology, Faculty of Medicine and University Hospital Carl Gustav Carus, Technische Universität Dresden, Helmholtz-Zentrum Dresden - Rossendorf, Dresden, Germany.

Background: Patient-specific quality assurance (PSQA) is a crucial yet resource-intensive task in proton therapy, requiring special equipment, expertise and additional beam time. Machine delivery log files contain information about energy, position and monitor units (MU) of all delivered spots, allowing a reconstruction of the applied dose. This raises the prospect of phantomless, log file-based QA (LFQA) as an automated replacement of current phantom-based solutions, provided that such an approach guarantees a comparable level of safety.

View Article and Find Full Text PDF

Integration of artificial intelligence (AI) into radiology practice can create opportunities to improve diagnostic accuracy, workflow efficiency, and patient outcomes. Integration demands the ability to seamlessly incorporate AI-derived measurements into radiology reports. Common data elements (CDEs) define standardized, interoperable units of information.

View Article and Find Full Text PDF

The ejaculatory reflex consists of emission and expulsion, with the latter involving rhythmic muscular contractions that propel seminal fluid. Botulinum toxin, through its inhibitory effects, has been hypothesized to improve premature ejaculation (PE). This study evaluates high-quality evidence on botulinum toxin-A injections into the bulbospongiosal muscle as a treatment for PE.

View Article and Find Full Text PDF

Approximately half of critically ill adults experience intensive care unit acquired weakness (ICUAW). Patients who develop ICUAW may have negative outcomes, including longer duration of mechanical ventilation, greater length of stay, and worse mobility, physical functioning, quality of life, and mortality. Early physical rehabilitation interventions have potential for improving ICUAW; however, randomized trials show inconsistent findings on the efficacy of these interventions.

View Article and Find Full Text PDF

Interleukin (IL) inhibitors are increasingly used in the management of moderate-to-severe plaque psoriasis. However, their use in patients with a history of cancer is debated. We conducted a multicenter retrospective study across nine Italian Dermatology Units to assess the real-world effectiveness and safety of IL inhibitors (IL-23, IL-17, IL-12/23) in 136 oncological patients with moderate-to-severe plaque psoriasis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!