We report here the construction and characterization of a high-power laser-induced acoustic desorption (LIAD) probe designed for Fourier transform ion cyclotron resonance mass spectrometers to facilitate analysis of nonvolatile, thermally labile compounds. This "next generation" LIAD probe offers significant improvements in sensitivity and desorption efficiency for analytes with larger molecular weights via the use of higher laser irradiances. Unlike the previous probes which utilized a power-limiting optical fiber to transmit the laser pulses through the probe, this probe employs a set of mirrors and a focusing lens. At the end of the probe, the energy from the laser pulses propagates through a thin metal foil as an acoustic wave, resulting in desorption of neutral molecules from the opposite side of the foil. Following desorption, the molecules can be ionized by electron impact or chemical ionization. Almost an order of magnitude greater power density (up to 5.0x10(9) W/cm2) is achievable on the backside of the foil with the high-power LIAD probe compared to the earlier LIAD probes (maximum power density approximately 9.0x10(8) W/cm2). The use of higher laser irradiances is demonstrated not to cause fragmentation of the analyte. The use of higher laser irradiances increases sensitivity since it results in the evaporation of a greater number of molecules per laser pulse. Measurement of the average velocities of LIAD-evaporated molecules demonstrates that higher laser irradiances do not correlate with higher velocities of the gaseous analyte molecules.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2547414PMC
http://dx.doi.org/10.1021/ac061597pDOI Listing

Publication Analysis

Top Keywords

higher laser
16
laser irradiances
16
liad probe
12
characterization high-power
8
high-power laser-induced
8
laser-induced acoustic
8
acoustic desorption
8
fourier transform
8
transform ion
8
ion cyclotron
8

Similar Publications

Background: The principal objective of our study is to evaluate the characteristics of babies with type 1 ROP, screening practices and treatment trends in a tertiary care centre in Pakistan.

Methods: This prospective study at Mayo Hospital, Lahore (July 2022-July 2024), included 89 preterm infants with type 1 ROP, selected using non-probability sampling. Infants were categorized based on international (GA < 32weeks or BW < 1500 g) and local screening criteria (GA < 35 weeks or BW < 2000 g), and treatment outcomes were evaluated across three groups: Anti-VEGF, combination therapy (Anti-VEGF followed by laser), and laser therapy.

View Article and Find Full Text PDF

To investigate the effect of the sizes of osteon-like concentric microgroove structures on the osteoclastic differentiation of macrophages on titanium surfaces, and to provide reference for the surface modification of implants. The silicon wafers sputtered with titanium were selected as the control group (smooth surface specimens) and four concentric groups (concentric circles with the maximum diameter of 200 μ m, the minimum diameter of 20 μ m, the spacing of concentric circles of 10 or 30 μm, the width of microgrooves of 10 or 30 μm, and the depth of microgrooves of 5 or 10 μm) specimens (the total sample size in each group was 27). The width of microgrooves of C10-5 and C10-10 groups was 10 μm, the depth was 5 and 10 μm, and the width of microgrooves of C30-5 and C30-10 groups was 30 μ m, the depth was 5 and 10 μ m, respectively.

View Article and Find Full Text PDF

Pre-trained Maldi Transformers improve MALDI-TOF MS-based prediction.

Comput Biol Med

January 2025

Department of Data Analysis and Mathematical Modelling, Ghent University, Coupure Links 653, Ghent, 9000, Belgium.

For the last decade, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has been the reference method for species identification in clinical microbiology. Hampered by a historical lack of open data, machine learning research towards models specifically adapted to MALDI-TOF MS remains in its infancy. Given the growing complexity of available datasets (such as large-scale antimicrobial resistance prediction), a need for models that (1) are specifically designed for MALDI-TOF MS data, and (2) have high representational capacity, presents itself.

View Article and Find Full Text PDF

Red and blue LED light increases the survival rate of random skin flaps in rats after MRSA infection.

Lasers Med Sci

January 2025

Department of Plastic and Reconstructive Surgery, The Second Affiliated Hospital of Anhui Medical University, 678 Furong Road, Hefei, Anhui Province, 230601, P.R. China.

Skin flap transplantation is a conventional wound repair method in plastic and reconstructive surgery, but infection and ischemia are common complications. Photobiomodulation (PBM) therapy has shown promise for various medical problems, including wound repair processes, due to its capability to accelerate angiogenesis and relieve inflammation. This study investigated the effect of red and blue light on the survival of random skin flaps in methicillin-resistant Staphylococcus aureus (MRSA)-infected Sprague Dawley (SD) rats.

View Article and Find Full Text PDF

This brief report aimed to investigate the optical absorbance spectra of normal, dysplastic, and malignant epithelial cell lines under normal and nutritional stress conditions. HaCAT (keratinocyte), DOK (oral dysplastic), and oral squamous cell carcinoma (OSCC) cell lines (CA1, Luc4, SCC9) were evaluated regarding their optical absorbance after culture with 0-10% fetal bovine serum. Absorbance measurements indicated that HaCAT under serum starvation exhibited higher absorbance at blue (430 nm) and near-infrared (906 nm) wavelengths.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!