Optical biopsy has been shown to discriminate between normal and diseased tissue with high sensitivity and specificity. Fiber-optic probe-based spectroscopy systems do not provide the necessary spatial information to guide therapy effectively, ultimately requiring a transition from probe-based spectroscopy to spectral imaging. The effect of such a transition on fluorescence and diffuse reflectance line shape is investigated. Inherent differences in spectral line shape between spectroscopy and imaging are characterized and many of these differences may be attributed to a shift in illumination-collection geometry between the two systems. Sensitivity of the line-shape disparity is characterized with respect to changes in sample absorption and scattering as well as to changes in various parameters of the fiber-optic probe design (e.g., fiber diameter, beam steering). Differences in spectral line shape are described in terms of the relative relationship between the light diffusion within the tissue and the distribution of source-detector separation distances for the probe-based and imaging illumination-collection geometries. Monte Carlo simulation is used to determine fiber configurations that minimize the line-shape disparity between the two systems. In conclusion, we predict that fiber-optic probe designs that mimic a spectral imaging geometry and spectral imaging systems designed to emulate a probe-based geometry will be difficult to implement, pointing toward a posteriori correction for illumination-collection geometry to reconcile imaging and probe-based spectral line shapes or independent evaluation of tissue discrimination accuracy for probe-based and spectral imaging systems.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/ao.46.001343 | DOI Listing |
Int Ophthalmol
January 2025
Department of Ophthalmology, Command Hospital, Pune, 411040, India.
Purpose: This study aimed to evaluate whether the digital eye strain (DES) was associated with the low central corneal thickness (CCT).
Methods: This observational cross-sectional pilot study was conducted from April 2023 to October 2023 at a tertiary eye care centre in North India, where CCT values were compared between subjects with DES and those without DES. Two hundred and eighty subjects (n = 280) aged 15-40 years with clear corneas and lenses were initially included in this study.
Eur Radiol Exp
January 2025
Department of Neuroradiology, University hospital RWTH Aachen, Aachen, Germany.
Background: To define optimal parameters for the evaluation of vessel visibility in intracranial stents (ICS) and flow diverters (FD) using photon-counting detector computed tomography angiography (PCD-CTA) with spectral reconstructions.
Methods: We retrospectively analyzed consecutive patients with implanted ICS or FD, who received a PCD-CTA between April 2023 and March 2024. Polyenergetic, virtual monoenergetic, pure lumen, and iodine reconstructions with different keV levels (40, 60, and 80) and reconstruction kernels (body vascular [Bv]48, Bv56, Bv64, Bv72, and Bv76) were evaluated by two radiologists with regions of interests and Likert scales.
Expert Rev Respir Med
January 2025
Medical Imaging Centre, Semmelweis University, Budapest, Hungary.
Am J Ophthalmol
January 2025
Centre for Public Health, Faculty of Medicine and Health Sciences, Queen's University Belfast, Belfast, Northern Ireland, United Kingdom. Electronic address:
Purpose: Color imaging is the accepted reference standard for detection of macular fibrosis in neovascular age-macular degeneration. Other imaging modalities of fluorescein angiography (FA) and spectral domain optical coherence tomography (SD-OCT) are also used but no formal agreement studies exist. We evaluated the agreement between fibrosis on colour, FA and SD-OCT-detected hyperreflective material (HRM) and their clinical relevance.
View Article and Find Full Text PDFSpectrochim Acta A Mol Biomol Spectrosc
January 2025
Key Laboratory of Spectral Imaging Technology, Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an 710119 China. Electronic address:
Non-optically active water quality parameters (NAWQPs) are essential for surface water quality assessments, although automated monitoring methods are time-consuming, include labor-intensive chemical pretreatment, and pose challenges for high spatiotemporal resolution monitoring. Advancements in spectroscopic techniques and machine learning may address these issues. We integrated ultraviolet-visible-near infrared absorption spectroscopy with physical-chemical measurements to predict total nitrogen (TN), dissolved oxygen (DO), and total phosphorus (TP) in the Yangtze River Basin, China.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!