Experience with combined transvenous pacemaker and implantable cardioverter-defibrillator insertion in 21 patients is described. Special techniques are needed to avoid potentially lethal pacemaker-implantable cardioverter-defibrillator interaction. Separation between leads for the two devices should be maximized. The electrophysiologic criteria for successful device function can be met, even when some leads for both devices must be placed by a transvenous approach.

Download full-text PDF

Source
http://dx.doi.org/10.1016/0003-4975(92)91327-6DOI Listing

Publication Analysis

Top Keywords

leads devices
8
methods implantable
4
implantable cardioverter-defibrillator-pacemaker
4
cardioverter-defibrillator-pacemaker insertion
4
insertion avoid
4
avoid interactions
4
interactions experience
4
experience combined
4
combined transvenous
4
transvenous pacemaker
4

Similar Publications

Background: Streptococcal Toxic Shock Syndrome (STSS) is a life-threatening condition caused by bacterial toxins. The STSS triad encompasses high fever, hypotensive shock, and a "sunburn-like" rash with desquamation. STSS, like Toxic Shock Syndrome (TSS), is a rare complication of streptococcal infec-tions caused by Group A Streptococcus (GAS), Streptococcal pyogenes (S.

View Article and Find Full Text PDF

Wound Healing Splinting Devices for Faster Access and Use.

JID Innov

March 2025

Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA.

With the goal of studying skin wound healing and testing new drug treatments to enhance wound healing in rodent models, there is a clear need for improved splinting techniques to increase surgical efficiency and support routine wound monitoring. Splinted wound healing models humanize wound healing in rodents to prevent contraction and instead heal through granulation tissue deposition, increasing the relevance to human wound healing. Current technologies require suturing and heavy wrapping, leading to splint failure and cumbersome monitoring of the wound.

View Article and Find Full Text PDF

Characterization of the tail current of Channelrhodopsin-2 variants.

Biochem Biophys Rep

September 2024

Chongqing Engineering Research Center of Medical Electronics and Information Technology, School of Bioinformatics, Chongqing University of Posts and Telecommunications, 400065, Chongqing, PR China.

Our study focused on specific ChR2 variants, particularly those with the Step function Opsins (SFO) mutation at the D156-C128 gate. These are widely used in optogenetics due to their heightened sensitivity to light and bi-stable prolonged activation. However, in some ChR2 variants, specifically D156 mutants, a tail current occurs when continuous light exposure is stopped.

View Article and Find Full Text PDF

Implantable hemodynamic devices like the CardioMEMS HF System are commonly used to manage fluid status in patients with heart failure (HF) by measuring pulmonary pressures. Although CardioMEMS has been shown to reduce HF hospitalizations, rare complications (eg, device endothelialization) can occur and warrant clinical attention. A 67-year-old woman with HF with preserved ejection fraction and group 2 pulmonary hypertension experienced recurrent HF exacerbations.

View Article and Find Full Text PDF

Cardiovascular disease is a leading cause of death worldwide. The differentiation of human pluripotent stem cells (hPSCs) into functional cardiomyocytes offers significant potential for disease modeling and cell-based cardiac therapies. However, hPSC-derived cardiomyocytes (hPSC-CMs) remain largely immature, limiting their experimental and clinical applications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!