A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Prospective monitoring study: isolating Legionella pneumophila in a hospital water system located in the obstetrics and gynecology ward after eradication of Legionella anisa and reconstruction of shower units. | LitMetric

We previously reported on the sporadic contamination by Legionella anisa of shower units and sink taps at Ryukyu University Hospital. Starting in July 2003, the neonatal area underwent an 8-month reconstruction, and in March 2005, the boiler system was replaced. We therefore examined shower water and tap water for the presence of Legionella just after replacement of the boiler system. In 3 of the 8 water samples collected from the remodeled area, we isolated Legionella pneumophila serogroup 1 and L. anisa. Moreover, L. pneumophila serogroup 1 was isolated in 4 of the 5 water samples gathered from the unreconstructed area of the same floor. Random amplified polymorphic DNA analysis suggested that a single clone of L. pneumophila might exist throughout the floors of the water distribution system. We replaced the shower units at the Legionella-positive site, and began flushing the sink-faucets with water heated to 55N for at least 1 h every morning. As a result, Legionella was not subsequently isolated in water samples. In this prospective study, we identified a central contamination by L. pneumophila serogroup 1 and showed that flushing with hot tap water was effective to counter this situation.

Download full-text PDF

Source

Publication Analysis

Top Keywords

shower units
12
water samples
12
pneumophila serogroup
12
water
9
legionella pneumophila
8
legionella anisa
8
boiler system
8
system replaced
8
tap water
8
isolated water
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!