In this study a real-time PCR assay using self-quenched primers labelled with a single fluorophore for the detection of Aeromonas salmonicida was developed. Probe specificity was confirmed by amplification of 16 A. salmonicida strain templates and by the lack of a PCR product with 26 non-A. salmonicida strains. With a pure culture of A. salmonicida, the assay was linear over a range of 0.5 pg to 50 ng and was able to detect 16 c.f.u. per reaction. A similar sensitivity was observed in DNA extracted from a mixture of A. salmonicida and fish tissue. Results using artificially inoculated tissues and diseased fish from outbreaks indicated that the assay can provide sensitive species-specific detection and quantification of A. salmonicida in fish tissue.