AI Article Synopsis

  • A TaqMan PCR system was developed to detect Pseudomonas aeruginosa bacteriophage PP7 in storm water samples, validating its use as a surrogate for performance tests of ultrafiltration systems.
  • The procedure demonstrated a 64% recovery rate of spiked PP7, with a detection limit of 5 gene copies, although variability in sample extraction efficiency was noted.
  • The analysis approach included a dilution method to mitigate PCR inhibition effects, allowing for more accurate quantification of viral pathogens, and aiming to understand the risk associated with specific pathogen detection limits.

Article Abstract

A quantitative real-time TaqMan PCR system for Pseudomonas aeruginosa bacteriophage PP7 was designed to detect PP7 as surrogate in performance tests of 2 hollow fiber ultrafiltration systems in series. Fifty-six storm water samples from 21 sites representing agricultural, urban and highway locations in California were collected. The optimized procedure gave recoveries of spiked PP7 of 64+/-4.8% (mean+/-SEM). The PP7 assay was validated over 5 orders of magnitude with an assay limit of detection of 5 gene copies per reaction volume. Sample-dependent variables like enzymatic inhibition during PCR analysis, filtration recovery and extraction efficiency were quantified and incorporated to calculate a specific sample limit of detection (S(LOD)) for the spiked surrogate PP7. S(LOD) values were highly variable among samples; they were independent of physicochemical parameters including conductivity, turbidity, total suspended solids and pH but strongly correlated with the dilution factor required to relieve enzymatic inhibition during PCR analysis. To determine actual gene copies of PP7, a dilution approach was developed that involves assaying several dilutions within a range where inhibitors do not affect the efficiency of amplification and linear regression to determine the theoretical C(t) value when there is no inhibition. For the detection of viral pathogens, an internal standard like PP7 can be used to calculate filtration recoveries when quantifying pathogens and to determine whether filtration or inhibitor concentration affect nucleic acid extraction efficiency. Additionally, by defining S(LOD) values per sample and pathogenic organism analyzed, it should be possible to critically investigate the absence of detects for a particular pathogen and determine probabilities of risk associated with a specific sample limit of detection.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.watres.2006.12.034DOI Listing

Publication Analysis

Top Keywords

limit detection
12
hollow fiber
8
fiber ultrafiltration
8
pp7
8
bacteriophage pp7
8
pp7 surrogate
8
water samples
8
gene copies
8
enzymatic inhibition
8
inhibition pcr
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!