Comparative accuracy of renal duplex sonographic parameters in the diagnosis of renal artery stenosis: paired and unpaired analysis.

AJR Am J Roentgenol

Centre for Kidney Research and Department of Nephrology, Children's Hospital at Westmead, Hawkesbury Rd. (Locked Bag 4001) Westmead, New South Wales 2145, Australia.

Published: March 2007

Objective: The purpose of this study was to evaluate the test performance of duplex sonographic parameters in screening for hemodynamically significant renal artery stenosis, which occurs in approximately 5% of persons with hypertension.

Materials And Methods: A comprehensive literature search was conducted to find studies on the diagnosis of renal artery stenosis in which duplex sonography and intraarterial angiography were compared and in which sensitivity and specificity were calculated. MEDLINE (1966-2005), EMBASE (1988-2005), and reference lists were searched and the authors contacted. Data were subjected to meta-analysis according to the hierarchical summary receiver operating characteristic curve model. Heterogeneity in test performance relating to population and design features was investigated.

Results: From 1,357 titles, 88 studies involving 9,974 arteries in 8,147 patients were included. The following four parameters were evaluated: peak systolic velocity (21 studies), acceleration time (13 studies), acceleration index (13 studies), and renal-aortic ratio (13 studies). The corresponding diagnostic odds ratios (ORs) were 60.9 (95% CI, 28.3-131.2), 28.9 (95% CI, 7.1-117.2), 16.0 (95% CI, 5.1-50.6), and 29.3 (95% CI, 12.7-67.7). Results based on studies in which parameters were directly compared showed that peak systolic velocity had greater accuracy than renal-aortic ratio (relative diagnostic OR, 1.8; p = 0.03; nine studies) and acceleration index (relative diagnostic OR, 5.3; p < 0.001; five studies). Acceleration time versus acceleration index showed no evidence of a difference in accuracy (relative diagnostic OR, 1.1; p = 0.65; nine studies). Analysis of peak systolic velocity used in combination with other parameters compared with peak systolic velocity alone (seven studies) showed evidence of a shift in test positivity (p < 0.001) but only weak evidence of improvement in accuracy (relative diagnostic OR, 1.6; p = 0.09).

Conclusion: Sonography is a moderately accurate screening test for renal artery stenosis. The single measurement, peak systolic velocity, has the highest performance characteristics, an expected sensitivity of 85% and specificity of 92%. Additional measurements do not increase accuracy.

Download full-text PDF

Source
http://dx.doi.org/10.2214/AJR.06.0355DOI Listing

Publication Analysis

Top Keywords

peak systolic
20
systolic velocity
20
renal artery
16
artery stenosis
16
studies acceleration
16
relative diagnostic
16
studies
11
duplex sonographic
8
sonographic parameters
8
diagnosis renal
8

Similar Publications

This study employed large eddy simulation (LES) with the wall-adapting local eddy-viscosity (WALE) model to investigate transitional flow characteristics in an idealized model of a healthy thoracic aorta. The OpenFOAM solver pimpleFoam was used to simulate blood flow as an incompressible Newtonian fluid, with the aortic walls treated as rigid boundaries. Simulations were conducted for 30 cardiac cycles and ensemble averaging was employed to ensure statistically reliable results.

View Article and Find Full Text PDF

Non-invasive estimation of pressure differences using 2D synthetic aperture ultrasound imaging offers a precise, low-cost, and risk-free diagnostic tool. Unlike invasive techniques, this preserves natural blood flow and avoids the limitations of devices that occupy lumen space. This paper evaluates a previously published estimator, modified to incorporate Singular Value Decomposition (SVD) echo-cancellation, using data from ten healthy volunteers and one patient.

View Article and Find Full Text PDF

A novel exercise protocol for cardiac rehabilitation aerobic (CRA) has been developed by Hebei Sport University, demonstrating efficacy in patients with coronary heart disease (CHD). The objective of this study was to evaluate the impact of CRA on precise cardiac rehabilitation (CR) for CHD patients presenting with stable angina pectoris. The study cohort comprised patients with stable angina who were categorized into three groups: the CRA group (n = 35), the power bicycles (PB) group (n = 34), and the control group (n = 43).

View Article and Find Full Text PDF

Aims: To describe the sonographic features of active Charcot neuro-osteoarthropathy (CNO) and assess the potential role of ultrasound in identifying those with active CNO.

Methods: Using a prospective case-series study design we assessed the sonographic features of 14 patients with a diagnosis of diabetes presenting with clinical signs and symptoms suspicious for active CNO. Patients had standard weight-bearing plain X-Ray and, where possible, MRI to evaluate the presence of active CNO.

View Article and Find Full Text PDF

Guanidinoacetic acid (GAA), a precursor of creatine, has a recognized effect on ruminant performance when used as a dietary supplement. However, its impact on reproductive response remains to be elucidated. Therefore, this study aimed to contribute initially to this area by supplementing the diets of ewes with a high dose of GAA, evaluating its effects on reproductive response.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!