A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Anterior-posterior thoracic force-deflection characteristics measured during cardiopulmonary resuscitation: comparison to post-mortem human subject data. | LitMetric

Anterior-posterior thoracic force-deflection characteristics measured during cardiopulmonary resuscitation: comparison to post-mortem human subject data.

Stapp Car Crash J

Center for Injury Research and Prevention, The Children's Hospital of Philadelphia, 34th and Civic Center Blvd, Suite 1024, Philadelphia, PA 19104, USA.

Published: November 2006

Comparative data of thoracic compression response between live vs. post mortem human subjects (PMHS) has been reported, but the live subject tests are often at low deflections and include the effects of muscle tensing. Novel technology has been developed that overcomes several of these limitations. Specifically, a load cell and accelerometer has been integrated into a clinical monitor-defibrillator to measure chest compression and applied force during live human cardio-pulmonary resuscitation (CPR). The sensor is interposed between the hands of the person administering CPR and the sternum of the patient. The objective of this study was to compare the thoracic force-deflection measured during adult CPR to that measured during hub-based loading of adult PMHS. CPR represents a unique setting in which to study the mechanics of the chest as the thorax is loaded to a maximum chest deflection similar to that seen in a frontal crash environment and the effects of muscle tensing are minimized. PMHS and CPR data were modeled with a progressive spring in parallel with a viscous damper. Statistical comparison of the model parameters used to describe the compliance of the thorax during large compressions revealed that under the specific loading conditions tested, chest compressions during CPR generated less force at equivalent deflections than the PMHS. Specifically, the spring force at 40 mm deflection was 286 N for the CPR data and 588 N for the PMHS. Differences in area of load application and thoracic structures engaged, however, may partially explain these differences. In addition, the chest response during CPR demonstrated more hysteresis than the PMHS suggesting that the viscoelastic nature of the thorax is more pronounced when tissues are naturally perfused and substantial tissue autolysis has not begun. This study presents fundamental biomechanical data on the mechanical response of the adult thorax that increases our understanding of any potential differences between PMHS and chest response obtained during CPR before substantial tissue autolysis begins. We contend that the thoracic compliance measured during CPR may continue to offer important force-deflection estimates in the future.

Download full-text PDF

Source
http://dx.doi.org/10.4271/2006-22-0006DOI Listing

Publication Analysis

Top Keywords

cpr
10
thoracic force-deflection
8
effects muscle
8
muscle tensing
8
pmhs cpr
8
cpr data
8
chest response
8
response cpr
8
substantial tissue
8
tissue autolysis
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!