Background: The role of computerised tomography (CT) lung density measurements in objective quantification of emphysema is uncertain. The aim of this study was to determine normal reference values for CT lung density measurements and investigate their utility in identifying subjects with clinical emphysema.
Methods: Normal subjects (non-smokers, no respiratory disease, n=185) and subjects with clinical emphysema (post-bronchodilator FEV(1)/FVC <70%, > or =10 pack years tobacco smoking, no childhood asthma and, either D(LCO)/VA <80% predicted and/or macroscopic emphysema on CT, n=22) were identified from a random population survey. Subjects underwent CT scanning, with measurement of areas of low attenuation as a percentage of total area (RA%) for three standardised slices and two reconstruction algorithms with a density threshold of -950 HU. Reference values in normal subjects, and ability of the measurements to discriminate between the two groups were determined.
Results: Reference values for individual subjects showed wide confidence intervals (standard resolution scans, RA% females 0.2-3.9%, males 0.4-8.7%.) Subjects with emphysema had greater RA% values compared with normal subjects, the difference being most marked in apical slices (standard resolution algorithm, apical slice, median RA% 2.9% (95% CI 0.4-11.1%) vs. 0.1% (95% CI 0.0-0.5%), emphysema vs. normal subjects, respectively). Logistic regression analysis showed poor discriminant ability to distinguish between the groups, the most favourable cut-off yielding a sensitivity and specificity of 83.3% and 62.8%, respectively.
Conclusions: CT lung density measurements cannot reliably detect the presence of emphysema in an individual. We recommend further investigation into lung density measurements before their widespread use in clinical practice.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.rmed.2007.01.002 | DOI Listing |
Atheroscler Plus
March 2025
Section of Inflammation and Cardiometabolic Diseases, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, MD, USA.
Background And Aims: Vitamin D binding protein (DBP) serves a dual function as a vitamin D carrier and actin scavenger. Free DBP is present in high concentrations in serum, while a smaller pool is bound to lipoproteins like HDL and VLDL. The role of DBP's interaction with lipoproteins remains unclear.
View Article and Find Full Text PDFEur J Radiol Open
June 2025
Department of Diagnostic Radiology, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Chiba 277-8577, Japan.
Purpose: The potential of spectral images, particularly electron density and effective Z-images, generated by dual-energy computed tomography (DECT), for the histopathologic classification of lung cancer remains unclear. This study aimed to explore which imaging factors could better reflect the histopathological status of lung cancer.
Method: The data of 31 patients who underwent rapid kV-switching DECT and subsequently underwent surgery for lung cancer were analyzed.
Medicine (Baltimore)
November 2024
Department of Radiology, Kantonsspital Baden, affiliated Hospital for Research and Teaching of the Faculty of Medicine of the University of Zurich, Baden, Switzerland.
The aim of our study was to evaluate the specific performance of an artificial intelligence (AI) algorithm for lung nodule detection in chest radiography for a larger number of nodules of different sizes and densities using a standardized phantom approach. A total of 450 nodules with varying density (d1 to d3) and size (3, 5, 8, 10 and 12 mm) were inserted in a Lungman phantom at various locations. Radiographic images with varying projections were acquired and processed using the AI algorithm for nodule detection.
View Article and Find Full Text PDFPhysiol Meas
January 2025
Chair of Measurements and Sensor Technology, Technische Universitat Chemnitz, Reichenhainerstrasse 70, Chemnitz, 09111, GERMANY.
Objective: Electrical Impedance Tomography (EIT) is a non-invasive technique used for lung imaging. A significant challenge in EIT is reconstructing images of deeper thoracic regions due to the low sensitivity of boundary voltages to internal conductivity variations. The current injection pattern is decisive as it influences the current path, boundary voltages, and their sensitivity to tissue changes.
View Article and Find Full Text PDFInsights Imaging
January 2025
Department of Diagnostic, Interventional and Paediatric Radiology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland.
Objectives: This study aimed to evaluate whether minimum-intensity projection (MinIP) images could predict complications in CT-guided lung biopsies.
Methods: We retrospectively analyzed 72 procedures from January 2019 to December 2023, categorizing patients by pneumothorax and the severity of hemorrhage (grade 2 or higher). Radiodensity measurements were performed using lung window (LW) and MinIP (10-mm slab) images.