A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Determining the quantity and character of carotid artery embolic debris by electron microscopy and energy dispersive spectroscopy. | LitMetric

Objectives: Carotid artery angioplasty and stenting (CAS) is now routinely performed with embolic protection devices, yet little is known about the compositional characteristics of the captured embolic debris and whether the type or quantity of debris correlates with patient, lesion, or operator characteristics. This study examined the embolic debris generated during CAS using electron microscopy and energy dispersive spectroscopy (EDS) for symptomatic and asymptomatic patients.

Methods: Between 2003 and 2005, CAS for carotid stenosis was performed in 175 patients. Cerebral protection devices were used in all but three cases. Sixty-four consecutive unselected microporous filters from procedures performed by a single vascular surgeon were obtained for analysis. Captured particulate debris within the protection devices was quantified (number and mean size of particles) by light microscopy for all filters. Twenty protection devices (9 symptomatic, 11 asymptomatic patients) were processed for electron microscopy and EDS to assess morphology, cellular composition, and calcium content of debris.

Results: Captured particulate matter was present in 49 filters (77%) and included particles measuring 200 to 500 mum in 72%, 500 to 1000 mum in 53%, and >1000 mum in 33%. The mean number of captured particles was 6.9, and mean size was 248 +/- 150 mum. Univariate analysis revealed that sequential patient cohort and filter type were correlated with the number (but not size) of captured particles. The number of particles significantly decreased after the first cohort of 20 patients (11.5 particles) compared with the second (5.0 particles, P = .023) and third (5.2 particles, P = .029) cohorts. The type of captured debris ranged from sheets of damaged red blood cells without other components to clumps of recently activated platelets with early fibrin crosslinking to plaque debris coated with well-organized coalescing areas of platelet thrombus. Platelet activation was more common in symptomatic patients (78%) than asymptomatic patients (27%; P < .05). Despite the presence of calcified lesions in six patients whose filters were analyzed by EDS, <1% of energy emission on EDS of scanned particulate debris fell within the emission range of calcium, indicating the presence of minimal calcium in the embolic particles.

Conclusions: Particulate embolic debris is released in most patients during CAS and can measure >1000 mum in one third of patients. The number of particles may decrease with increasing operator experience with CAS. Debris captured during CAS with embolic protection exhibits a range of cellular and acellular components on electron microscopy, with a higher prevalence of platelet activation evident in symptomatic patients.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jvs.2006.12.015DOI Listing

Publication Analysis

Top Keywords

electron microscopy
16
protection devices
16
embolic debris
12
particles
9
carotid artery
8
debris
8
microscopy energy
8
energy dispersive
8
dispersive spectroscopy
8
embolic protection
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!