Initial osteogenesis at the implant interface is, to a great extent, determined by the implant surface characteristics and the interfacial loading conditions. The present study investigated the effect of various degrees of relative movement on the tissue differentiation around a roughened screw-shaped immediately loaded implant. Repeated-sampling bone chambers were installed in the tibia of 10 rabbits. In each of the chambers, three experiments were performed by inducing 0 (control), 30, and 90 microm implant displacement for 9 wk. A linear mixed model and a logistic mixed model with alpha = 5% determined statistical significance. Tissue filling of the bone chamber was similar for the three test conditions. The bone area fraction was significantly higher for 90 microm implant displacement compared with no displacement. A significantly higher fraction of bone trabeculae was found for 30 and 90 microm implant displacement compared with the unloaded situation. The incidence of osteoid-to-implant and bone-to-implant contact was significantly higher for 90 microm implant displacement compared with 30 and 0 microm implant displacement. Significantly more osteoid in contact with the implant was found for the loaded conditions compared with no loading. Well-controlled micro-motion positively influenced bone formation at the interface of a roughened implant. An improved bone reaction was detected with increasing micro-motion.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1600-0722.2007.00416.xDOI Listing

Publication Analysis

Top Keywords

microm implant
20
implant displacement
20
displacement compared
12
implant
10
mixed model
8
higher microm
8
bone
6
displacement
6
microm
5
micro-motion tissue
4

Similar Publications

Purpose: To evaluate objective and subjective results after bilateral implantation of a diffractive trifocal intraocular lens (IOL) in a Mexican population.

Methods: Prospective, interventional case series involved 15 cataract surgery patients who underwent bilateral implantation of the trifocal Micro F lens FineVision IOL (PhysIOL, Liège, Belgium). Objective analysis involved assessment of monocular uncorrected distance (UDVA), near (UNVA) at 30 and 40 cm, and intermediate visual acuity (UIVA) at 50, 60, and 70 cm, preoperatively, and at postoperative months 1, 3, and 6.

View Article and Find Full Text PDF

Global platelet hyperreactivity and elevated C-reactive protein levels predict long term mortality in STEMI patients.

Thromb Res

October 2014

Department of Experimental and Clinical Medicine, University of Florence, Centre for the study at molecular and clinical level of chronic, degenerative and neoplastic diseases to develop novel therapies, University of Florence, Florence, Italy.

Background: Data on long term - more than 1-year - prognostic value of global platelet reactivity (G-HPR) - by adenosine diphosphate (ADP) and arachidonic acid (AA) - in patients with STEMI undergoing PCI are limited. High C-reactive protein (CRP) levels have been suggested to be associated with post-PCI atherothrombotic events. Our aim was to evaluate the long-term prognostic impact of G-HPR and CRP levels in STEMI patients.

View Article and Find Full Text PDF

Dynamic contrast enhanced (DyCE) fluorescence imaging was recently demonstrated for identifying the organs in mice based on principal component analysis (PCA) of contrast kinetics following infusion of indocyanine green (ICG). It occurred to us that this approach could be used to evaluate acute effects of vascular disrupting agents (VDAs), since these cause massive vascular shutdown. As proof of principle, we have examined the action of combretastatin-A4P (CA4P) on MCF7 human breast tumors growing in nude mice.

View Article and Find Full Text PDF

Objective: To investigate development of a cell extraction process for preparing human meniscus acellular matrix, and morphology and biomechanical properties.

Methods: Human meniscus were subjected to modified eight-step detergent, then, the specimens were assessed by staining with haematoxylin-eosin, toluidine blue, sirius red, saffron O, alcain blue and hoechst-33258, et al. The ultrastructure of the specimens was observed with scanning electron microscope.

View Article and Find Full Text PDF

The purpose of this study was to evaluate the in vitro macrophage compatibility, the inflammatory response and in vivo host response to a novel collagen-chitosan (COL-CS) scaffold containing growth factors incorporated Chitosan Nanoparticle (CNP). The scaffold was obtained by freezing a blend of COL-CS solution and growth factor incorporated CNP followed by lyophilization. High Resolution Transmission Electron Micrograph (HR-TEM) indicated that growth factors incorporated CNP were in the size range of 50-100 nm, while Scanning Electron Microscopic (SEM) analysis of the scaffold surface suggests that the pores of the scaffolds (COL-CS) were well interconnected, with a mean diameter of 75-150 microm.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?