Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: Simple, 2-compartment mathematical models of middle ear (ME) transmucosal gas exchange reproduce observed ME pressure behavior. These models require input of an experimentally determined, lumped-parameter exchange constant for each represented gas species. Previous model applications assumed directional asymmetry for those parameters, which has not been experimentally validated.
Methods: As a surrogate for the inert gas nitrogen (N2), for which exchange is too slow to be measurable, the nitrous oxide (N2O) transmucosal exchange constant for 16 ears of 8 monkeys was measured for positive and negative ME blood N20 gradients.
Results: The paired exchange constants for each ear were highly correlated, but the ME-blood/blood-ME exchange constant ratio was approximately 13. Modeling shows this asymmetry to depend on the value of the arterial-venous/arterialME ratio, a variable in the exchange constant for perfusion-limited gases.
Conclusions: These results support an asymmetric rate of transmucosal N20 and, by extension, N2 exchange for the ME. Because the primary controlling parameter for ME pressure behavior in the absence of eustachian tube opening is the rate of transmucosal N2 exchange, this effect needs to be incorporated into the simple 2-compartment exchange models for predictive accuracy. The gradient ratio dependence suggests that parameter-free modeling may require treating the ME mucosa as having a distributed gradient for certain gas species.