Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To investigate the efficacy and safety of a capacitively coupled, pulsed electrical stimulation device in treating knee osteoarthritis (OA).
Design: Fifty-eight outpatients with moderate to severe OA of the knee entered a 3-month, double-blind, placebo-controlled trial, using either an active or placebo device at home for 6 to 14 h/day. Outcome measures included a patient global evaluation, a patient report of knee pain severity, and the Western Ontario and McMaster Universities (WOMAC) questionnaire.
Results: Active treatment provided superior outcomes between baseline and 3-month follow-up measurements: 50.6% greater improvement than placebo in patient global (P=0.03), 31.2% in patient pain (P=0.04), 25.1% in WOMAC stiffness (P=0.03), 29.5% in WOMAC function (P=0.01), 19.9% in WOMAC pain (P=0.11), and 27% in total WOMAC (P=0.01). The percent of patients who improved by more than 50% was 38.5 active vs 5.3 placebo in patient global (P=0.01), 43.6 vs 15.8 in patient pain (P=0.04), 38.5 vs 10.5 in WOMAC pain (P=0.03), 28.2 vs 5.3 in WOMAC stiffness (P=0.08), 23.1 vs 5.3 in WOMAC function (P=0.14), and 23.1 vs 5.3 in total WOMAC (P=0.14). Twenty-one percent of placebo and 18% of actively treated patients developed a transient rash at the electrode sites. No other adverse device effects were reported.
Conclusion: A highly optimized, capacitively coupled, pulsed electrical stimulus device significantly improved symptoms and function in knee OA without causing any serious side effects.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.joca.2007.01.004 | DOI Listing |