A framework for the prediction of scale-up when using compressible chromatographic packings.

Biotechnol Prog

Innovative Manufacturing Research Centre, Advanced Centre for Biochemical Engineering, University College London, Torrington Place, London WC1E 7JE, United Kingdom.

Published: May 2007

Experimental data are given for the solid pressure distributions in chromatography columns of various column aspect ratios packed with four types of agarose-based resin. The loss of column wall support at large scales can result in unexpectedly high pressures caused by the compression of the matrix via drag forces exerted by fluid flow through the bed. The need for an accurate model to predict flow conditions at increasing scale is essential for the scaling-up of chromatographic processes and for avoiding bed compression during operation. Several studies have generated correlations that allow for the prediction of column pressure drops, but they either are mathematically complex, which impairs their practical use, or require a large number of experiments to be performed before they can be used. In this study an empirical correlation was developed based on a previously proposed model, which links the critical velocity of operation of a chromatographic system (microcrit), to the gravity-settled bed height (L0), the column diameter (D), the feed viscosity (micro), and the compressibility of the chromatographic media used (micro 10%). The methodology developed in this study is straightforward to use and significantly reduces the burden of preceding laboratory-scale experimentation. The approach can be used to predict the critical velocity of any chromatographic system and will be useful in the development of chromatographic operations and for column sizing.

Download full-text PDF

Source
http://dx.doi.org/10.1021/bp060303iDOI Listing

Publication Analysis

Top Keywords

critical velocity
8
chromatographic system
8
chromatographic
6
column
5
framework prediction
4
prediction scale-up
4
scale-up compressible
4
compressible chromatographic
4
chromatographic packings
4
packings experimental
4

Similar Publications

Fluid administration is widely used to treat hypotension in patients undergoing veno-venous extracorporeal membrane oxygenation (VV-ECMO). However, excessive fluid administration may lead to fluid overload can aggravate acute respiratory distress syndrome (ARDS) and increase patient mortality, predicting fluid responsiveness is of great significance for VV-ECMO patients. This prospective single-center study was conducted in a medical intensive care unit (ICU) and finally included 51 VV-ECMO patients with ARDS in the prone position (PP).

View Article and Find Full Text PDF

Perfusion Pressures and Weight Loss During Normothermic Machine Perfusion of Human Donor Livers.

Artif Organs

December 2024

Department of Surgery, Section of Hepatobiliary Surgery and Liver Transplantation, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands.

Background: Normothermic machine perfusion (NMP) is increasingly used to preserve and assess donor livers prior to transplantation. Due to its success, it is expected that more centers will start using this technology. However, NMP may also cause adverse effects.

View Article and Find Full Text PDF

Pressure-improved Scott-Vogelius type elements.

Calcolo

December 2024

Institut für Mathematik, Universität Zürich, Winterthurerstr 190, 8057 Zürich, Switzerland.

The Scott-Vogelius element is a popular finite element for the discretization of the Stokes equations which enjoys inf-sup stability and gives divergence-free velocity approximations. However, it is well known that the convergence rates for the discrete pressure deteriorate in the presence of certain in a triangulation of the domain. Modifications of the Scott-Vogelius element such as the recently introduced pressure-wired Stokes element also suffer from this effect.

View Article and Find Full Text PDF

Density-dependent flow generation in active cytoskeletal fluids.

Sci Rep

December 2024

Department of Chemical Engineering, Kyoto University, Nishi-kyoku, Kyoto, 615-8510, Japan.

The actomyosin cytoskeleton, a protein assembly comprising actin fibers and the myosin molecular motor, drives various cellular dynamics through contractile force generation at high densities. However, the relationship between the density dependence of the actomyosin cytoskeleton and force-controlled ordered structure remains poorly understood. In this study, we measured contraction-driven flow generation by varying the concentration of cell extracts containing the actomyosin cytoskeleton and associated nucleation factors.

View Article and Find Full Text PDF

Previous studies demonstrated that dexmedetomidine (Dex) posttreatment aggravated myocardial dysfunction and reduced survival in septic mice. Yet, whether Dex elicits similar effects in septic patients as defined by Sepsis-3 remains unknown. This study sought to assess the effects of Dex-based sedation on mortality and cardiac dysfunction in septic patients defined by Sepsis-3 and to further reveal the mechanisms in septic rats.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!