Ischemia-modified albumin is a highly sensitive serum marker of transient myocardial ischemia induced by coronary vasospasm.

Coron Artery Dis

Department of Internal Medicine, Hanmaeum General Hospital, and Jeju Department of Emergency Medicine, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.

Published: March 2007

Background: Ischemia-modified albumin, a new marker of myocardial ischemia, is known to elevate during ischemia induced by percutaneous coronary intervention. It is, however, not known whether ischemia-modified albumin also elevates during transient coronary vasospasm.

Methods: We evaluated ischemia-modified albumin in patients undergoing intracoronary ergonovine spasm provocation test (n=26). For additional comparison, ischemia-modified albumin was also evaluated in elective percutaneous coronary intervention patients (n=18) and in patients with normal coronary angiography (n=10). Blood samples were taken from the arterial sheath before the procedure, just after procedural completion, or balloon inflation.

Results: Median ischemia-modified albumin level elevated significantly in patients with positive provocation test compared with baseline [n=16, 106.0 (interquartile range 96.5, 115.5) versus 128.5 (114.8, 171.8) U/ml, P<0.001], whereas it did not change in patients with negative provocation test [n=10, 109.5 (103.3, 115.0) versus 113.5 (104.0, 118.3) U/ml, P=0.108]. Ischemia-modified albumin was also higher after percutaneous coronary intervention [113.5 (101.0, 131.5) versus 151.0 (129.3, 231.0) U/ml, P<0.0001] and did not change in patients with normal coronary angiography [108.5 (99.3, 114.0) versus 110.0 (108.0, 114.0) U/ml, P=0.085]. Ischemia-modified albumin elevation higher than 9 U/ml after provocation test could detect the presence of coronary vasospasm, with an area under the receiver operating characteristic curve of 0.975 (95% confidence interval 0.921-1.000), with a sensitivity of 94% and a specificity of 99%. Serum albumin levels were within reference range for all patients and there was no significant relationship between albumin and baseline ischemia-modified albumin or postischemic ischemia-modified albumin.

Conclusion: Thus, ischemia-modified albumin may have a role as a biochemical marker for transient myocardial ischemia induced by coronary vasospasm.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MCA.0b013e328010a49fDOI Listing

Publication Analysis

Top Keywords

ischemia-modified albumin
24
myocardial ischemia
8
ischemia induced
8
percutaneous coronary
8
coronary intervention
8
provocation test
8
ischemia-modified
6
coronary
5
albumin
5
albumin highly
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!