The precedence effect describes the phenomenon whereby echoes are spatially fused to the location of an initial sound by selectively suppressing the directional information of lagging sounds (echo suppression). Echo suppression is a prerequisite for faithful sound localization in natural environments but can break down depending on the behavioral context. To date, the neural mechanisms that suppress echo directional information without suppressing the perception of echoes themselves are not understood. We performed in vivo recordings in Mongolian gerbils of neurons of the dorsal nucleus of the lateral lemniscus (DNLL), a GABAergic brainstem nucleus that targets the auditory midbrain, and show that these DNLL neurons exhibit inhibition that persists tens of milliseconds beyond the stimulus offset, so-called persistent inhibition (PI). Using in vitro recordings, we demonstrate that PI stems from GABAergic projections from the opposite DNLL. Furthermore, these recordings show that PI is attributable to intrinsic features of this GABAergic innervation. Implementation of these physiological findings into a neuronal model of the auditory brainstem demonstrates that, on a circuit level, PI creates an enhancement of responsiveness to lagging sounds in auditory midbrain cells. Moreover, the model revealed that such response enhancement is a sufficient cue for an ideal observer to identify echoes and to exhibit echo suppression, which agrees closely with the percepts of human subjects.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6673727 | PMC |
http://dx.doi.org/10.1523/JNEUROSCI.5335-06.2007 | DOI Listing |
Rheumatol Int
January 2025
Department of Diagnostic and Interventional Radiology, University Hospital Wuerzburg, Oberduerrbacher Strasse 6, 97080, Wuerzburg, Germany.
Background: Diagnosis of Giant Cell Arteritis (GCA) and Polymyalgia rheumatica (PMR) may be challenging as many patients present with non-specific symptoms. Superficial cranial arteries are predilection sites of inflammatory affection. Ultrasound is typically the diagnostic tool of first choice supplementary to clinical and laboratory examination.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Radiology, Renmin Hospital of Wuhan University, No. 238 Jiefang Road, Wuchang District, Wuhan, 430060, China.
Follicle count, a pivotal metric in the adjunct diagnosis of polycystic ovary syndrome (PCOS), is often underestimated when assessed via transvaginal ultrasonography compared to MRI. Nevertheless, the repeatability of follicle counting using traditional MR images is still compromised by motion artifacts or inadequate spatial resolution. In this prospective study involving 22 PCOS patients, we employed periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) and single-shot fast spin-echo (SSFSE) T2-weighted sequences to suppress motion artifacts in high-resolution ovarian MRI.
View Article and Find Full Text PDFPLoS One
December 2024
Department of Materials and Production, Aalborg University, Aalborg, Denmark.
Background: In magnetic resonance imaging (MRI) segmentation research, the choice of sequence influences the segmentation accuracy. This study introduces a method to compare sequences. By aligning sequences with specific segmentation objectives, we provide an example of a comparative analysis of various sequences for knee images.
View Article and Find Full Text PDFJ Orthop Traumatol
December 2024
Sapienza Universitiy, Rome, Italy.
Introduction: The plantar plate, also called the plantar ligament, is a fibrocartilaginous structure found in the metatarsophalangeal (MTP) and interphalangeal (IP) joints. Our study aimed to evaluate the role of magnetic resonance imaging (MRI) performed with the patient in the standard position or with joint hyperextension (the "stress test", ST) in the study of plantar plate (PP) disease that involves metatarsophalangeal joints.
Materials And Methods: All patients underwent forefoot MRI (Atroscan C, Esaote, Genoa, Italy), operating at 0.
Quant Imaging Med Surg
December 2024
Department of Medical Imaging, the People's Hospital of Liuyang, Liuyang, China.
Background: Anal fistula is a common anorectal disorder that significantly diminishes the quality of life for affected patients. Accurate preoperative evaluation of the fistula's traits is essential for customizing surgical strategies, improving patient outcomes, and reducing the likelihood of the disease returning. This study aimed to evaluate the diagnostic accuracy of multi-phase contrast-enhanced fat-suppressed T1-weighted imaging using three-dimensional gradient echo sequence volumetric interpolated breath-hold examination (CE-FS-T1-3D-VIBE) and fat-suppressed T2-weighted imaging combined with diffusion-weighted imaging (FS-T2WI-DWI) sequence in delineating the characteristics of anal fistulas.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!