Background: The present study examines the safety and feasibility of using a remote magnetic navigation system to perform endocardial and epicardial substrate-based mapping and radiofrequency ablation in patients with scar-related ventricular tachycardia (VT).

Methods And Results: Using the magnetic navigation system, we performed 27 procedures on 24 consecutive patients with a history of VT related to myocardial infarction, dilated cardiomyopathy, arrhythmogenic right ventricular cardiomyopathy, hypertrophic cardiomyopathy, or sarcoidosis. Electroanatomic mapping of the left ventricular, right ventricular, and ventricular epicardial surfaces was constructed in 24, 10, and 12 patients, respectively. Complete-chamber VT activation maps were created in 4 patients. A total of 77 VTs were inducible, of which 21 were targeted during VT with the remotely navigated radiofrequency ablation catheter alone. With a combination of entrainment and activation mapping, 17 of 21 VTs (81%) were successfully terminated in a mean of 8.4+/-8.2 seconds; for the remainder, irrigated radiofrequency ablation was necessary. The mean fluoroscopy times for endocardial and epicardial mapping were 27+/-23 seconds (range, 0 to 105 seconds) and 18+/-18 seconds (range, 0 to 49 seconds), respectively. In concert with a manually navigated irrigated ablation catheter, 75 of 77 VTs (97%) were ultimately ablated. Four patients underwent a second procedure for recurrent VT, 3 with the magnetic navigation system. After 1.2 procedures per patient, VT did not recur during a mean follow-up of 7+/-3 months (range, 2 to 12 months).

Conclusions: The present study demonstrates the safety and feasibility of remote catheter navigation to perform substrate mapping of scar-related VT in a wide range of disease states with a minimal amount of fluoroscopy exposure.

Download full-text PDF

Source
http://dx.doi.org/10.1161/CIRCULATIONAHA.106.672162DOI Listing

Publication Analysis

Top Keywords

magnetic navigation
16
endocardial epicardial
12
navigation system
12
radiofrequency ablation
12
remote magnetic
8
mapping scar-related
8
scar-related ventricular
8
ventricular tachycardia
8
safety feasibility
8
feasibility remote
8

Similar Publications

This study aims to develop and validate a standardized methodology for creating high-fidelity, custom-made, patient-specific 3D-printed vascular models that serve as tools for preoperative planning and training in the endovascular treatment of peripheral artery disease (PAD). Ten custom-made 3D-printed vascular models were produced using computed tomography angiography (CTA) scans of ten patients diagnosed with PAD. CTA images were analyzed using Syngo.

View Article and Find Full Text PDF

Magnetic Ball Chain Robots for Cardiac Arrhythmia Treatment.

IEEE Trans Med Robot Bionics

November 2024

Department of Cardiovascular Surgery, Boston Children's Hospital, Harvard Medical School, Boston, MA 02115, USA.

This paper introduces a novel magnetic navigation system for cardiac ablation. The system is formed from two key elements: a magnetic ablation catheter consisting of a chain of spherical permanent magnets; and an actuation system comprised of two cart-mounted permanent magnets undergoing pure rotation. The catheter design enables a large magnetic content with the goal of minimizing the footprint of the actuation system for easier integration with the clinical workflow.

View Article and Find Full Text PDF

Our visual system enables us to effortlessly navigate and recognize real-world visual environments. Functional magnetic resonance imaging (fMRI) studies suggest a network of scene-responsive cortical visual areas, but much less is known about the temporal order in which different scene properties are analysed by the human visual system. In this study, we selected a set of 36 full-colour natural scenes that varied in spatial structure and semantic content that our male and female human participants viewed both in 2D and 3D while we recorded magnetoencephalography (MEG) data.

View Article and Find Full Text PDF

Magneto-Photochemically Responsive Liquid Crystal Elastomer for Underwater Actuation.

ACS Appl Mater Interfaces

January 2025

Faculty of Engineering and Natural Sciences, Tampere University, P.O. Box 541, FI-33101 Tampere, Finland.

The quest for small-scale, remotely controlled soft robots has led to the exploration of magnetic and optical fields for inducing shape morphing in soft materials. Magnetic stimulus excels when navigation in confined or optically opaque environments is required. Optical stimulus, in turn, boasts superior spatial precision and individual control over multiple objects.

View Article and Find Full Text PDF

In this investigation, we delve into the neural underpinnings of auditory processing of Sanskrit verse comprehension, an area not previously explored by neuroscientific research. Our study examines a diverse group of 44 bilingual individuals, including both proficient and non-proficient Sanskrit speakers, to uncover the intricate neural patterns involved in processing verses of this ancient language. Employing an integrated neuroimaging approach that combines functional connectivity-multivariate pattern analysis (fc-MVPA), voxel-based univariate analysis, seed-based connectivity analysis, and the use of sparse fMRI techniques to minimize the interference of scanner noise, we highlight the brain's adaptability and ability to integrate multiple types of information.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!