Purpose: The purpose of this retrospective, blinded study was to evaluate the additional value of [18F]FDG PET/CT in comparison with PET alone and with side-by-side PET and CT in patients with malignant melanoma (MM).

Methods: A total of 127 consecutive studies of patients with known MM referred for a whole-body PET/CT examination were included in this study. PET alone, side-by-side PET and CT and integrated PET/CT study were independently and separately interpreted without awareness of the clinical information. One score each was applied for certainty of lesion localisation and for certainty of lesion characterisation. Verification of the findings was subsequently performed using all available clinical, pathological (n=30) and follow-up information.

Results: The number of lesions with an uncertain localisation was significantly (p<0.001) reduced by PET/CT and side-by-side PET and CT (p<0.05) in comparison with PET alone. In line with this increase in certainty integrated PET/CT reading also improved certainty in characterisation of lesions, however, this did not reach significance (p=0.057) compared versus PET alone. Respectively, PET, side-by-side PET and CT and PET/CT showed a sensitivity of 86%, 89% and 91%, a specificity of 94%, 94% and 94%, a positive predictive value of 96%, 96% and 96% and a negative predictive value of 80%, 83% and 87%.

Conclusion: Integrated PET/CT offers a significant benefit in lesion localisation and an improvement in lesion characterisation compared with PET alone or with side-by-side PET and CT. The benefit is not as great as that reported for other tumour entities, which may be due to the high avidity of MM for [18F]FDG.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00259-006-0358-1DOI Listing

Publication Analysis

Top Keywords

pet side-by-side
12
side-by-side pet
12
[18f]fdg pet/ct
8
pet patients
8
patients malignant
8
malignant melanoma
8
certainty lesion
8
pet
6
direct comparison
4
comparison [18f]fdg
4

Similar Publications

Radiometal chelator conjugation is a cornerstone of radioimmunotherapy (RIT). Continued interest in selective placement of chelators remains an active topic of discussion in the field. With several simple site-specific methods being recently reported, it was of interest to investigate the benefits and potential drawbacks of the site-specific method with a full comparison to a more typical random conjugation method that is currently utilized in clinical applications.

View Article and Find Full Text PDF
Article Synopsis
  • - This study compares polymeric micelles and single-chain nanoparticles (SCNPs) as drug delivery systems, focusing on their internalization by breast cancer cells and macrophages.
  • - Researchers synthesized various copolymers and analyzed how the solvent impacts the self-assembly and resultant structure of these nanoparticles, emphasizing the role of solvent in photocross-linking.
  • - The findings revealed that using acetonitrile for cross-linking resulted in better-defined nanoparticles with higher cellular uptake and identified passive transport as the primary mechanism for delivery into MCF-7 cells.
View Article and Find Full Text PDF

Chelator boosted tumor-retention and pharmacokinetic properties: development of Cu labeled radiopharmaceuticals targeting neurotensin receptor.

Eur J Nucl Med Mol Imaging

September 2024

Department of Radiology, Biomedical Research Imaging Center, Lineberger Comprehensive Cancer Center, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina , 27599, USA.

Purpose: Accumulating evidence suggests that neurotensin (NTS) and neurotensin receptors (NTSRs) play key roles in lung cancer progression by triggering multiple oncogenic signaling pathways. This study aims to develop Cu-labeled neurotensin receptor 1 (NTSR1)-targeting agents with the potential for both imaging and therapeutic applications.

Method: A series of neurotensin receptor antagonists (NRAs) with variable propylamine (PA) linker length and different chelators were synthesized, including [Cu]Cu-CB-TE2A-iPA-NRA ([Cu]Cu-4a-c, i = 1, 2, 3), [Cu]Cu-NOTA-2PA-NRA ([Cu]Cu-4d), [Cu]Cu-DOTA-2PA-NRA ([Cu]Cu-4e, also known as [Cu]Cu-3BP-227), and [Cu]Cu-DOTA-VS-2PA-NRA ([Cu]Cu-4f).

View Article and Find Full Text PDF

Background: Advanced positron emission tomography (PET) image reconstruction methods promise to allow optimized PET/CT protocols with improved image quality, decreased administered activity and/or acquisition times.

Objective: To evaluate the impact of reducing counts (simulating reduced acquisition time) in block sequential regularized expectation maximization (BSREM) reconstructed pediatric whole-body F-fluorodeoxyglucose (FDG) PET images, and to compare BSERM with ordered-subset expectation maximization (OSEM) reconstructed reduced-count images.

Materials And Methods: Twenty children (16 male) underwent clinical whole-body F-FDG PET/CT examinations using a 25-cm axial field-of-view (FOV) digital PET/CT system at 90 s per bed (s/bed) with BSREM reconstruction (β=700).

View Article and Find Full Text PDF

An F-MD-PSMA (Multi-dentate PMSA Imaging Agent) PET/CT in Prostate Cancer Relapse: Results of a Retrospective Trial.

Curr Radiopharm

September 2024

Shanghai Ruxu Biotechnology, Inc, 4777 North Jia-Song Road, Jiading District, Shanghai, 201814, China.

Purpose: This study aimed to evaluate the performance of 18F-MD-PSMA PET/CT in patients previously treated for prostate cancer by either surgery or therapy, but later relapsed biochemically.

Methods: This retrospective study enrolled 213 patients in sequence previously treated for prostate cancer by either surgery or therapy, but later PSA relapsed. A total of 191 of these 213 patients were included in this analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!