Purpose: This study was designed to evaluate the frequency and nature of neovascularization in age-related macular degeneration (ARMD) utilizing the combination of digital imaging techniques, fluorescein angiography (FA), indocyanine green (ICG) angiography, and optical coherence tomography (OCT).
Methods: A complete clinical examination was performed on 100 eyes of 93 consecutive newly diagnosed patients with neovascular ARMD. Digital fluorescein angiography, ICG angiography, and OCT were also used in evaluating those patients. Comparison of the imaging techniques to determine their value in studying the nature of the lesions.
Results: On the basis of existing fluorescein standards, 15 eyes were diagnosed with classic choroidal neovascularization (CNV), 15 with minimally classic CNV, and 70 with occult CNV. ICG angiography was superior for detecting the active vascular component in polypoidal CNV (16 eyes) and retinal angiomatous proliferation (14 eyes). OCT was more sensitive than FA for determining the presence of cystoid macular edema evident in the vast majority of eyes with retinal angiomatous proliferation (RAP).
Conclusions: These results suggest that FA, ICG angiography, and OCT, when used in combination, will assist clinicians in best determining the precise nature of the neovascular process in ARMD.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/112067210701700111 | DOI Listing |
Anal Chem
January 2025
Center for Advanced Materials Research & Faculty of Arts and Sciences, Beijing Normal University, Zhuhai 519087, P. R. China.
The development of long-wavelength near-infrared II (NIR-II, 900-1700 nm) dyes is highly desirable but challenging. To achieve both red-shifted absorption/emission and superior imaging capabilities, a donor-acceptor-donor (D-A-D) xanthene core was strategically modified by extending π-conjugated double bonds and enhancing electron-donating properties. Two dyes named and were synthesized and exhibited notably red-shifted absorption/emission peaks at 942/1250 and 1098/1450 nm, respectively.
View Article and Find Full Text PDFActa Neurochir (Wien)
January 2025
Department of Neurosurgery, The Fourth Affiliated Hospital of Soochow University, Suzhou, China.
Background: Superficial temporal artery (STA)-middle cerebral artery (MCA) side-to-side microvascular anastomosis can achieve the same clinical effects as traditional STA-MCA end-to-side anastomosis in extracranial-intracranial revascularization surgery, furthermore, STA-MCA side-to-side anastomosis has the lower risk of postoperative cerebral hyperperfusion syndrome (CHS) and the potential to recruit all scalp arteries as the donor sources via self-regulation. Therefore, STA-MCA side-to-side microvascular anastomosis seems to be a revascularization strategy superior to traditional STA-MCA end-to-side anastomosis. In this study, we presented seven cases in which a STA-MCA side-to-side microvascular anastomosis was performed with a 4-5 mm long arteriotomy using the in-situ intraluminal suturing technique.
View Article and Find Full Text PDFTech Coloproctol
January 2025
Université Laval, 10, De l'Espinay St, Quebec City, QC, G1L 3L5, Canada.
Background: Inadequate bowel perfusion is among risk factors for colorectal anastomotic leaks. Perfusion can be assessed with indocyanine green fluorescence angiography (ICG) during colon resections. Possible benefits from its systematic use in high-risk patients with rectal cancer remain inconsistent.
View Article and Find Full Text PDFInt J Mol Sci
December 2024
Gordon Center for Medical Imaging, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, USA.
Despite significant advancements in bioimaging technology, only a limited number of fluorophores are currently approved for clinical applications. Indocyanine green (ICG) is the first FDA-approved near-infrared (NIR) fluorophore and has significantly advanced clinical interventions over the past three decades. However, its single-channel imaging at 800 nm emission is often insufficient for capturing comprehensive diagnostic information during surgery.
View Article and Find Full Text PDFMedicina (Kaunas)
November 2024
Department of Electronic Engineering, Pusan National University, Busan 46241, Republic of Korea.
: This study aimed to determine the minimal effective dose of indocyanine green (ICG) required for accurately assessing colonic perfusion during laparoscopic colorectal surgery using a laser-assisted laparoscopic near-infrared (NIR) camera system. : In 15 patients with colorectal cancer undergoing right hemicolectomy, the left branch of the middle colic artery was preserved, and ICG angiography was performed in the transverse colon. To determine the optimal ICG dose, experimental doses of 0.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!