[Application of polytetrafluoroethylene as VEGF gene carrier].

Zhejiang Da Xue Xue Bao Yi Xue Ban

The Second Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310009, China.

Published: January 2007

Objective: To investigate the feasibility of vascular graft material polytetrafluoroethylene (PTFE) as gene carrier of vascular endothelial growth factor (VEGF).

Methods: The PTFE strips were soaked in pCDI-hVEGF(121) solution,marked with EB solution, and then observed under ultraviolet light. The PTFE strips carrying pCDI-hVEGF(121) were soaked in normal saline and the value of optical density at 260 nm on different time was measured, then the controlled release curve was made. The PTFE strips carrying pCDI-hVEGF(121) were implanted into the left thigh muscles of rabbits and the PTFE strips without VEGF gene were implanted into the right. The expression of VEGF(121) mRNA versus beta-actin mRNA in muscles around vascular graft materials was evaluated by reverse transcriptase polymerase chain reaction(RT-PCR). The expression of VEGF(121) protein in muscle was determined by Western blot method.

Result: The fluorescence on PTFE strips carrying pCDI-hVEGF(121) was observed under ultraviolet light. The controlled release curve demonstrated that the gene release was fast during 0.5 -4 h, then slowed down afterwards,and lasted for 72 h. RT-PCR and Western blot showed VEGF(121)/beta-actin mRNA ratios were 1.053+/-0.356,1. 718+/-0.404, 2.021+/-0.303, 1.872+/-0.231, 0.986+/-0.254, 0.340+/-0.116 and VEGF(121)protein expression levels were 0.328+/-0.088, 1.019+/-0.105, 2.249 +/-0.203, 2.036+/-0.079, 1.670+/-0.132, 0.636+/-0.107 at 1, 7, 14, 28, 42, and 56 days after implantation, respectively.

Conclusion: The PTFE graft can be used as carrier of VEGF gene and VEGF gene can be transferred to skeletal muscle by this method.

Download full-text PDF

Source
http://dx.doi.org/10.3785/j.issn.1008-9292.2007.01.010DOI Listing

Publication Analysis

Top Keywords

ptfe strips
20
vegf gene
16
strips carrying
12
carrying pcdi-hvegf121
12
vascular graft
8
observed ultraviolet
8
ultraviolet light
8
controlled release
8
release curve
8
expression vegf121
8

Similar Publications

Per- and polyfluoroalkyl substances (PFAS) are used in the production of PTFE based coatings for cookware. In this study, emission of PFAS and further volatile organic compounds (VOC) from kitchenware articles were investigated. First, method development for thermal extraction of baking trays, frying pans and baking mats at 250 °C was done by testing three different extraction devices.

View Article and Find Full Text PDF

With the development of 5G technology, the accurate measurement of the complex permittivity of a printed circuit board (PCB) in the wide frequency range is crucial for the design of high-frequency circuits. In this paper, a microwave measurement device and method based on the double-sided parallel-strip line (DSPSL) resonator have been developed to measure the complex permittivity of typical PCBs in the vertical direction. The device includes the DSPSL resonator, the DSPSL coupling probe, a pressure monitor, a Farran C4209 vector network analyzer (100 K to 9 GHz), and a FEV-10-PR-0006 frequency multiplier (75-110 GHz).

View Article and Find Full Text PDF

Objective: Microbial keratitis (MK) is a significant cause of blindness in sub-Saharan Africa. We investigated the feasibility of using a novel corneal impression membrane (CIM) for obtaining and processing samples by culture, PCR and whole-genome sequencing (WGS) in patients presenting with suspected MK in Malawi.

Methods And Analysis: Samples were collected from patients presenting with suspected MK using a 12 mm diameter polytetrafluoroethylene CIM disc.

View Article and Find Full Text PDF

Purpose: This study evaluates surgical outcomes and complication rates of frontalis suspension with expanded polytetrafluoroethylene (ePTFE).

Methods: This retrospective cohort study reviewed all patients undergoing frontalis suspension surgery using ePTFE as the sling material from January 1 2012 to March 3 2020 by a single surgeon at a single academic center. Two different surgical techniques were evaluated in the placement of the sling material.

View Article and Find Full Text PDF

Aortic annuloplasty has been clearly demonstrated to have a protective influence in aortic valve repair. Over the past 20 years, different annuloplasty concepts have been proposed by different groups. However, the most appropriate approach to enable long-term annular stability remains highly controversial.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!