A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The safe limits of mechanical factors in the apnea testing for the diagnosis of brain death. | LitMetric

The safe limits of mechanical factors in the apnea testing for the diagnosis of brain death.

Tohoku J Exp Med

Department of Anesthesiology and Reanimation, Dokuz Eylül University, School of Medicine, Izmir, Turkey.

Published: February 2007

Apneic oxygenation is an apnea testing method in the diagnosis of brain death. In this method, oxygen (O2) is delivered into the trachea via an O2 catheter (O2C). However, barotrauma may develop during O2 insufflation into the trachea. Oxygen catheter diameters, O2 catheter tip position in the trachea, and O2 flow rate have been proposed as causes of barotrauma. This study was designed to highlight the airway pressure changes during apneic oxygenation in a model consisting of an anesthesia bag, which was connected to a pressure transducer and to an endotracheal tube (ETT). The pressure of the system was monitored while delivering O2 continuously to the system through O2C of different diameters, which were placed in the ETT. Tested variables were ETT/O2C ratio, O2C tip position in ETT (proximal 1/3 of the ETT, mid point of the ETT, and distal 1/3 of the ETT) and O2 flow rate (6, 8, and 10 L min(-1)). The increase in the airway pressure significantly correlated with O2C tip position in ETT (p = 0.017). ETT/O2C ratio smaller than 1.75 caused significantly high airway pressures (p < 0.05). The pressure was significantly higher at the flow rate of 10 L min(-1) O2 compared with the flow rate of 6 L min(-1) O2 (p < 0.01). Thus, ETT/O2C ratio, O2C tip position in ETT and O2 flow rate are the important factors that determine the airway pressure in the trachea during O2 insufflation. In conclusion, overlooked mechanical factors dangerously increase airway pressure during apnea testing.

Download full-text PDF

Source
http://dx.doi.org/10.1620/tjem.211.115DOI Listing

Publication Analysis

Top Keywords

flow rate
20
airway pressure
16
apnea testing
12
ett/o2c ratio
12
o2c position
12
position ett
12
rate min-1
12
mechanical factors
8
diagnosis brain
8
brain death
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!