Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Apneic oxygenation is an apnea testing method in the diagnosis of brain death. In this method, oxygen (O2) is delivered into the trachea via an O2 catheter (O2C). However, barotrauma may develop during O2 insufflation into the trachea. Oxygen catheter diameters, O2 catheter tip position in the trachea, and O2 flow rate have been proposed as causes of barotrauma. This study was designed to highlight the airway pressure changes during apneic oxygenation in a model consisting of an anesthesia bag, which was connected to a pressure transducer and to an endotracheal tube (ETT). The pressure of the system was monitored while delivering O2 continuously to the system through O2C of different diameters, which were placed in the ETT. Tested variables were ETT/O2C ratio, O2C tip position in ETT (proximal 1/3 of the ETT, mid point of the ETT, and distal 1/3 of the ETT) and O2 flow rate (6, 8, and 10 L min(-1)). The increase in the airway pressure significantly correlated with O2C tip position in ETT (p = 0.017). ETT/O2C ratio smaller than 1.75 caused significantly high airway pressures (p < 0.05). The pressure was significantly higher at the flow rate of 10 L min(-1) O2 compared with the flow rate of 6 L min(-1) O2 (p < 0.01). Thus, ETT/O2C ratio, O2C tip position in ETT and O2 flow rate are the important factors that determine the airway pressure in the trachea during O2 insufflation. In conclusion, overlooked mechanical factors dangerously increase airway pressure during apnea testing.