To construct an appropriate motor command from signals that provide a representation of desired action, the nervous system must take into account the dynamic characteristics of the motor plant to be controlled. In the oculomotor system, signals specifying desired eye velocity are thought to be transformed into motor commands by an inverse dynamic model of the eye plant that is shared for all types of eye movements and implemented by a weighted combination of eye velocity and position signals. Neurons in the prepositus hypoglossi and adjacent medial vestibular nuclei (PH-BT neurons) were traditionally thought to encode the "eye position" component of this inverse model. However, not only are PH-BT responses inconsistent with this theoretical role, but compensatory eye movement responses to translation do not show evidence for processing by a common inverse dynamic model. Prompted by these discrepancies between theoretical notions and experimental observations, we reevaluated these concepts using multiple-frequency rotational and translational head movements. Compatible with the notion of a common inverse model, we show that PH-BT responses are unique among all premotor cell types in bearing a consistent relationship to the motor output during eye movements driven by different sensory stimuli. However, because their responses are dynamically identical to those of motoneurons, PH-BT neurons do not simply represent an internal component of the inverse model, but rather its output. They encode and distribute an estimate of the motor command, a signal critical for accurate motor execution and learning.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6673592 | PMC |
http://dx.doi.org/10.1523/JNEUROSCI.3822-06.2007 | DOI Listing |
Neurol Int
November 2024
Department of Radiology, Section Neuroradiology, Lucerne Cantonal Hospital, 6000 Lucerne, Switzerland.
Objectives: Blood pressure (BP) management is challenging in patients with acute ischemic supratentorial stroke undergoing recanalization therapy due to the lack of established guidelines. Assessing dynamic cerebral autoregulation (dCA) may address this need, as it is a bedside technique that evaluates the transfer function phase in the very low-frequency (VLF) range (0.02-0.
View Article and Find Full Text PDFNeuroimage
December 2024
Medical Image Processing Department, CHU Amiens-Picardie University Hospital, Amiens, France; CHIMERE UR 7516, University of Picardie Jules Verne, Amiens, France. Electronic address:
Understanding cerebrospinal fluid (CSF) dynamics is crucial for elucidating the pathogenesis and diagnosis of neurodegenerative diseases. The primary mechanisms driving CSF oscillations remain a topic of debate. This study investigates whether cerebral blood volume displacement (CBV), modulated by breathing and cardiac activity, are the predominant drivers of CSF oscillations.
View Article and Find Full Text PDFProbl Radiac Med Radiobiol
December 2024
National Cancer Institute of the Ministry of Health of Ukraine, 33/43 33/43 Yulia Zdanovska Str., Kyiv, 03022, Ukraine.
Unlabelled: Patients with breast cancer (BC) are at high risk of cardiotoxicity (CT) due to combination of anticancer treatment.Cardio-vascular (СV) complications lead to the delay or discontinuation of anticancer therapy, which significantlyworsens the prognosis. Anthracyclines (AC) are the main drugs included in most anticancer treatment regimens.
View Article and Find Full Text PDFAngew Chem Int Ed Engl
December 2024
University of Wisconsin-Madison, Chemical and Biological Engineering, 1415 Engineering Drive, 53706, Madison, UNITED STATES OF AMERICA.
In this study, we employed EC-MS to elucidate the role of halide anions in electrochemical CO2 and CO reduction. We found that the undesired hydrogen evolution reaction (HER) was significantly suppressed by the anion used. Specifically, the rates of H2 production decreased in the order KF > KCl > KI, meaning that I- most strongly suppressed HER.
View Article and Find Full Text PDFJ Neural Eng
December 2024
University of California San Francisco, 513 Parnassus Avenue, S362, SAN FRANCISCO, San Francisco, 94143, CHINA.
Objective: Electroencephalography (EEG) and Magnetoencephalography (MEG) are widely used non-invasive techniques in clinical and cognitive neuroscience. However, low spatial resolution measurements, partial brain coverage by some sensor arrays, as well as noisy sensors could result in distorted sensor topographies resulting in inaccurate reconstructions of underlying brain dynamics. Solving these problems has been a challenging task, This paper proposes a robust framework based on electromagnetic source imaging for interpolation of unknown or poor quality EEG/MEG measurements.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!