Stimulus evoked electromyography is currently used during surgery to prevent nerve root injury during iliosacral screw insertion. In order to evaluate the importance of anode location in this procedure, a three dimensional finite element model was constructed from computed tomography data to evaluate the effectiveness of five electrode locations. Three anode locations (CASIS, dorsal midline and ventral midline) performed well, including the one most commonly used clinically (ventral midline). The dorsal midline, ventral midline, and CASIS anode locations provide data on the proximity to the neural structure in the superior, inferior and contralateral directions respectively that were attenuated at other anode locations. Modification of the technique to include monitoring of multiple anode locations could further reduce the incidence of injury.

Download full-text PDF

Source
http://dx.doi.org/10.1109/IEMBS.2005.1617274DOI Listing

Publication Analysis

Top Keywords

anode locations
16
ventral midline
12
stimulus evoked
8
iliosacral screw
8
screw insertion
8
finite element
8
element model
8
dorsal midline
8
midline ventral
8
anode
5

Similar Publications

Electroacupuncture (EA) is one of the most commonly used methods in acupuncture and has a good effect on pain, depression, sensory movement disorders, and other diseases. The effectiveness of EA is influenced by many factors, such as the accuracy of acupoint selection, the duration and course of EA treatment, and EA parameters. However, it has rarely been discussed whether the positive and negative electrodes of the EA instrument with acupoints at different locations and distances have an effect on the curative effect.

View Article and Find Full Text PDF

Transformer-based neural speech decoding from surface and depth electrode signals.

J Neural Eng

January 2025

Electrical and Computer Engineering Department, New York University, 370 Jay Street, Brooklyn, New York, New York, 10012-1126, UNITED STATES.

This study investigates speech decoding from neural signals captured by intracranial electrodes. Most prior works can only work with electrodes on a 2D grid (i.e.

View Article and Find Full Text PDF

Transcutaneous spinal direct current stimulation (TSDCS) has the potential to modulate spinal circuits and induce functional changes in humans. Nevertheless, differences across studies on basic parameters used and obtained metrics represent a confounding factor. Computer simulations are instrumental in improving the application of the TSDCS technique.

View Article and Find Full Text PDF

The human visual system is tuned to symmetry, and the neural response to visual symmetry has been well studied. One line of research measures an Event Related Potential (ERP) component called the Sustained Posterior Negativity (SPN). Amplitude is more negative at posterior electrodes when participants see symmetrical patterns compared to asymmetrical patterns.

View Article and Find Full Text PDF

The precise localization of epileptic foci with the help of EEG or iEEG signals is still a clinical challenge with current methodology, especially if the foci are not close to individual electrodes. On the research side, dipole reconstruction for focus localization is a topic of recent and current developments. Relatively low numbers of recording electrodes cause ill-posed and ill-conditioned problems in the inversion of lead-field matrices to calculate the focus location.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!