We have focused on the usage of MCNP code for calculation of Gamma Knife radiation field parameters with a homogenous polystyrene phantom. We have investigated several parameters of the Leksell Gamma Knife radiation field and compared the results with other studies based on EGS4 and PENELOPE code as well as the Leksell Gamma Knife treatment planning system Leksell GammaPlan (LGP). The current model describes all 201 radiation beams together and simulates all the sources in the same time. Within each beam, it considers the technical construction of the source, the source holder, collimator system, the spherical phantom, and surrounding material. We have calculated output factors for various sizes of scoring volumes, relative dose distributions along basic planes including linear dose profiles, integral doses in various volumes, and differential dose volume histograms. All the parameters have been calculated for each collimator size and for the isocentric configuration of the phantom. We have found the calculated output factors to be in agreement with other authors' works except the case of 4 mm collimator size, where averaging over the scoring volume and statistical uncertainties strongly influences the calculated results. In general, all the results are dependent on the choice of the scoring volume. The calculated linear dose profiles and relative dose distributions also match independent studies and the Leksell GammaPlan, but care must be taken about the fluctuations within the plateau, which can influence the normalization, and accuracy in determining the isocenter position, which is important for comparing different dose profiles. The calculated differential dose volume histograms and integral doses have been compared with data provided by the Leksell GammaPlan. The dose volume histograms are in good agreement as well as integral doses calculated in small calculation matrix volumes. However, deviations in integral doses up to 50% can be observed for large volumes such as for the total skull volume. The differences observed in treatment of scattered radiation between the MC method and the LGP may be important in this case. We have also studied the influence of differential direction sampling of primary photons and have found that, due to the anisotropic sampling, doses around the isocenter deviate from each other by up to 6%. With caution about the details of the calculation settings, it is possible to employ the MCNP Monte Carlo code for independent verification of the Leksell Gamma Knife radiation field properties.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1118/1.2401054 | DOI Listing |
Med Phys
January 2025
Deparment of Radiation Oncology, Duke University, Durham, North Carolina, USA.
Background: Stereotactic radiosurgery (SRS) is widely used for managing brain metastases (BMs), but an adverse effect, radionecrosis, complicates post-SRS management. Differentiating radionecrosis from tumor recurrence non-invasively remains a major clinical challenge, as conventional imaging techniques often necessitate surgical biopsy for accurate diagnosis. Machine learning and deep learning models have shown potential in distinguishing radionecrosis from tumor recurrence.
View Article and Find Full Text PDFNeurosurgery
January 2025
Department of Biomedical Sciences, Humanitas University, Milan, Italy.
Background And Objectives: Understanding and managing seizure activity is crucial in neuro-oncology, especially for highly epileptogenic lesions like isocitrate dehydrogenase (IDH)-mutant gliomas. Advanced MRI techniques such as diffusion tensor imaging (DTI) and neurite orientation dispersion and density imaging (NODDI) have been used to describe microstructural changes associated with epilepsy. However, their role in tumor-related epilepsy (TRE) remains unclear.
View Article and Find Full Text PDFNeurosurgery
January 2025
Department of Neurological Surgery, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.
Background And Objectives: Jugular paragangliomas (JPG) pose a surgical challenge because of their vascularity and complex location. Stereotactic radiosurgery (SRS) offers a minimally invasive management for patients with JPG. Our aim was to evaluate outcomes of Gamma Knife radiosurgery (GKRS) for the treatment of JPG over the long term.
View Article and Find Full Text PDFSci Rep
January 2025
Radiation Safety and Quality Assurance division, National Cancer Center Hospital East, Chiba, 277-8577, Japan.
The impact of three-dimensional (3D) dose delivery accuracy of C-arm linacs on the planning target volume (PTV) margin was evaluated for non-coplanar intracranial stereotactic radiosurgery (SRS). A multi-institutional 3D starshot test using beams from seven directions was conducted at 22 clinics using Varian and Elekta linacs with X-ray CT-based polymer gel dosimeters. Variability in dose delivery accuracy was observed, with the distance between the imaging isocenter and each beam exceeding 1 mm at one institution for Varian and nine institutions for Elekta.
View Article and Find Full Text PDFEur J Cancer
January 2025
National Center for Cancer Immune Therapy, Department of Oncology, Copenhagen University Hospital, Herlev, Denmark. Electronic address:
Introduction: Advances in modern therapies have improved outcomes for patients with melanoma brain metastases (MBM), though prognosis remains poor. The optimal treatment strategy for patients who do not meet clinical trial inclusion criteria is unclear.
Methods: This study included all patients with MBM diagnosed in Denmark between 2015 and 2022, identified through the Danish Metastatic Melanoma Database (DAMMED) and local surgical and radiotherapy records.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!