A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The effect of low-intensity pulsed ultrasound on bone healing in SR-PLLA rod fixed experimental distal femur osteotomy in rat. | LitMetric

The effects of low-intensity pulsed ultrasound (30 mW/cm2) were investigated in experimental cancellous bone fracture healing in bioabsorbable self-reinforced poly-L-lactide (SR-PLLA) rod fixed distal femur osteotomy in rats. A transverse transcondylar osteotomy was fixed with one SR-PLLA rod in 32 male Wistar rats of the age of 20 weeks. Half of the rats had a daily 20-min ultrasound exposure for three weeks. The follow-up times were three, six, and 12 weeks. Radiographical, histological, microradiographical, oxytetracycline labeling, and histomorphometrical analyses were performed. No foreign-body reactions were noted. The biocompatibility of SR-PLLA and ultrasound was found to be good. In the radiological and histological assessments there was a slight tendency for enhanced healing in the ultrasound group at three weeks, but at six and 12 weeks no differences were observed. The histomorphometrical and oxytetracycline labeling analyses showed that ultrasound exposure had no significant effects on bone healing. The present study shows that there were no obvious findings to support the hypothesis that low-intensity pulsed ultrasound enhances bone healing in self-reinforced poly-L-lactide (SR-PLLA) rod fixed experimental metaphyseal distal femur osteotomy in rats. The observed good biocompatibility provides a safe starting-point for clinical trials on bioabsorbable fixation combined with low-intensity ultrasound.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10856-006-0096-8DOI Listing

Publication Analysis

Top Keywords

sr-plla rod
16
low-intensity pulsed
12
pulsed ultrasound
12
bone healing
12
rod fixed
12
distal femur
12
femur osteotomy
12
three weeks
12
ultrasound
8
fixed experimental
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!