The use of cannulated screws for internal fixation of slipped capital femoral epiphysis (SCFE) is recognized as the standard method of treatment and has fewer complications compared with previous methods such as pins or tri-flanged nails. Some complications related to guidewires have been reported in the treatment SCFE. The most dangerous complication is inadvertent advance of the guidewire into the pelvic cavity. Guidewire breakage is frequent and maybe under-reported. Articular migration of a guidewire fragment has potentially devastating effects and implies a second surgical procedure. Open arthrotomy is the traditional method for fragment removal from the hip joint. We report the case of a 12-year-old-girl with bilateral SCFE. Both hips were fixed with cannulated screws. A guidewire broke inside her right hip, leaving an articular fragment located at the inferior-posterior acetabular notch. Hip arthroscopy was performed 6 weeks after the index procedure; the fragment was located and removed from the joint. No evidence of cartilage damage other than the perforation created by the guidewire was found. Hip arthroscopy is an attractive option for articular foreign body removal; it has the potential for less morbidity and is adequate for evaluating and treating articular cartilage lesions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arthro.2005.08.048DOI Listing

Publication Analysis

Top Keywords

guidewire fragment
8
hip joint
8
fixation slipped
8
slipped capital
8
capital femoral
8
femoral epiphysis
8
cannulated screws
8
fragment located
8
hip arthroscopy
8
guidewire
6

Similar Publications

Introduction: Delayed union, non-union, and unstable fixation can lead to fatigue fractures of orthopedic implants. Breakages typically occur at the fracture site or locking screw insertion, acting as stress concentration foci. This case report highlights a rare instance of a 3-part broken proximal femoral nail (PFN), extracted using a corticotomy-assisted method without knee joint violation.

View Article and Find Full Text PDF

Introduction: Horseshoe kidney is often associated with ureteropelvic junction obstruction and nephrolithiasis. Retrograde intrarenal surgery (RIRS) is becoming one of the main treatment options for large stones in such patients.

Aim: To study the results of RIRS in patients with horseshoe kidney.

View Article and Find Full Text PDF

A device that can evaluate human pulmonary microcirculation is currently unavailable. This study aimed to establish a novel approach for assessing pulmonary microcirculation in patients with pulmonary hypertension (PH). We used a guidewire embedded with temperature and pressure sensors to measure the following pulmonary microcirculatory function indicators: pulmonary flow reserve, pulmonary index of microcirculatory resistance (PIMR), and pulmonary resistive reserve ratio.

View Article and Find Full Text PDF
Article Synopsis
  • * A case study details a 72-year-old woman who developed a pseudoaneurysm in her SGA three weeks after surgery, which manifested as a hematoma and was successfully treated with embolization.
  • * Early detection and management of SGA injuries are crucial, with methods like CT angiography aiding diagnosis, and surgeons should exercise caution during procedures to avoid increasing the chance of such injuries.
View Article and Find Full Text PDF

Consequences and management of guidewire fracture-entrapment in the left circumflex artery: a case report.

Eur Heart J Case Rep

August 2024

Consultant Interventional Cardiologist, Moulana Hospital, Mysuru - Ooty Rd, Perintalmanna, Kerala 679322, India.

Article Synopsis
  • Entrapment and fracture of coronary guidewires during percutaneous coronary intervention (PCI) are rare but serious complications, occurring in less than 1% of cases.
  • A 52-year-old male patient with heart issues faced a guidewire fracture while treating an artery occlusion, requiring multiple techniques to remove the wire. Eventually, the triple-wire technique was used, which successfully extracted the fragment but caused some complications that were later managed with stenting.
  • The case emphasizes the effectiveness of the triple-wire technique for removing fractured guidewires and notes that leaving the wire in place may be considered a safe option if asymptomatic.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!