Objectives: The goal of this work was to verify whether the superiority of the sirolimus-eluting stent (SES) in inhibiting neointimal hyperplasia could be demonstrated in complex coronary lesions.
Background: Both the SES (Cypher, Cordis, Miami Lakes, Florida) and the paclitaxel-eluting stent (PES) (Taxus, Boston Scientific, Natick, Massachusetts) have shown a marked reduction in neointimal hyperplasia compared with bare-metal stents. Intravascular ultrasound (IVUS) is the best method to assess arterial response to stent deployment, but few IVUS data are available comparing complex lesions treated with SES or PES.
Methods: We prospectively randomized patients with complex lesions to SES or PES implantation. Intravascular ultrasound and quantitative angiography were performed post-procedure and at 9 months. Mean neointimal hyperplasia area (NIHA), percent of NIHA (NIHA%), mean peristent plaque area (PSPA), and percent of PSPA (PSPA%) were calculated. The primary end point was NIHA% at follow-up. Secondary end points included change in PSPA% and angiographic late luminal loss at follow-up.
Results: Of the 100 patients enrolled, 42 receiving the SES and 43 receiving the PES had adequate IVUS assessment. Vessel, plaque, and lumen areas were comparable at follow-up, but NIHA% was significantly lower with SES than PES (7.4 +/- 4.2% vs. 15.4 +/- 8.1%; p < 0.001). A significant reduction in PSPA% was observed with SES (-4 +/- 10% vs. 0 +/- 8%; p = 0.01). Late loss was significantly lower with SES (0.16 +/- 0.19 mm vs. 0.32 +/- 0.33 mm; p = 0.003).
Conclusions: The SES shows a significantly higher inhibition of neointimal hyperplasia compared with PES in complex lesions. However, both stents have excellent IVUS and angiographic results at 9 months. A significant reduction in peri-stent plaque is observed only with SES.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jacc.2006.09.042 | DOI Listing |
Rev Cardiovasc Med
December 2024
Department of Cardiology, University Clinical Center of Serbia, 11000 Belgrade, Serbia.
Background: Elective unprotected left main (ULM) percutaneous coronary intervention (PCI) has long-term mortality rates comparable to surgical revascularization, thanks to advances in drug-eluting stent (DES) design, improved PCI techniques, and frequent use of intravascular imaging. However, urgent PCI of ULM culprit lesions remains associated with high in-hospital mortality and unfavourable long-term outcomes, including DES restenosis and stent thrombosis (ST). This analysis aimed to examine the long-term outcomes and healing of DES implanted in ULM during primary PCI using high-resolution optical coherence tomography (OCT) imaging.
View Article and Find Full Text PDFACS Nano
December 2024
Department of Cardiology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou 310016, China.
Synthetic vascular grafts are promising conduits for small caliber arteries. However, due to restenosis caused by intimal hyperplasia, they cannot keep long patency in vivo. In this work, through single cell RNA sequencing, we found that thrombospondin-1 (THBS1) was highly expressed in the regenerated smooth muscle cells (SMCs) in electrospun polycaprolactone (PCL) vascular grafts.
View Article and Find Full Text PDFJ Mech Behav Biomed Mater
December 2024
Department of Biomedical Engineering, The University of Utah, 36 S Wasatch Dr, Salt Lake City, UT, 84112, USA; Department of Biomedical Engineering, Texas A&M University, 101 Bizzell St, College Station, TX, 77843, USA; Scientific Computing and Imaging Institute, The University of Utah, 72 Central Campus Dr, Salt Lake City, UT, 84112, USA; School of Engineering Medicine, Texas A&M University, 1020 Holcombe Blvd., Houston, TX, 77030, USA; Department of Multidisciplinary Engineering, Texas A&M University, 101 Bizzell St, College Station, TX, 77843, USA; Department of Cardiovascular Sciences, Houston Methodist Academic Institute, 6565 Fannin Street, Houston, TX, 77030, USA. Electronic address:
The failure of synthetic small-diameter vascular grafts has been attributed to a mismatch in the compliance between the graft and native artery, driving mechanisms that promote thrombosis and neointimal hyperplasia. Additionally, the buckling of grafts results in large deformations that can lead to device failure. Although design features can be added to lessen the buckling potential (e.
View Article and Find Full Text PDFFood Funct
December 2024
Department of Heart Center, The Third Central Hospital of, Tianjin, 300170, China.
Despite the significant alleviation of clinical cardiovascular diseases through appropriate interventional treatments, the recurrence of vascular restenosis necessitating reoperation remains a substantial challenge impacting patient prognosis. Plant-derived exosome-like nanovesicles (PELNs) are integral to interspecies cellular communication, with their functions and potential applications garnering significant attention from the research community. This study extracted -derived exosome-like nanovesicles (SL-ELNs) and demonstrated their inhibition of PDGF-BB-induced proliferation, migration, and phenotypic transformation of vascular smooth muscle cells (VSMCs).
View Article and Find Full Text PDFInt J Biol Macromol
December 2024
Department of Vascular Surgery, Xuan Wu Hospital and Institute of Vascular Surgery, Capital Medical University, Beijing 100053,China. Electronic address:
In clinical practice, the demand for functional small-diameter vascular grafts continues to increase. In this study, a decellularized aorta artery was inserted into a poly(caprolactone) (PCL) vascular scaffold for self-assembly in-vitro to create a hybrid scaffold. The hybrid scaffold was then implanted subcutaneously into the dorsal flanks and the subcutaneous extracellular matrix was applied for bilayer adhesion.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!