Simultaneous reconstruction of maxillary and nasal deformity in a patient with Binder's syndrome (maxillonasal dysplasia).

J Oral Maxillofac Surg

Department of Oral and Maxillofacial Surgery, School of Dental Medicine, University of Pittsburgh, PA 15261.

Published: January 1992

Download full-text PDF

Source
http://dx.doi.org/10.1016/0278-2391(92)90205-eDOI Listing

Publication Analysis

Top Keywords

simultaneous reconstruction
4
reconstruction maxillary
4
maxillary nasal
4
nasal deformity
4
deformity patient
4
patient binder's
4
binder's syndrome
4
syndrome maxillonasal
4
maxillonasal dysplasia
4
simultaneous
1

Similar Publications

Vascularised Composite Allotransplantation - A guide to optimal dissemination of scientific outputs.

J Hand Microsurg

January 2025

Tissue Engineering Research Group (TERG), Department of Anatomy and Regenerative Medicine, RCSI University of Medicine and Health Sciences, Dublin, Ireland.

Purpose: The impact of academic research is not just important within the clinical domain but within society as a whole. Altmetric Attention Score (AAS) offers a means of assessing how scholarly outputs are interacted with online. Vascularised Composite Allotransplantation (VCA) is a modern but rapidly evolving topic which encompasses a broad range of complex and clinically significant surgical interventions.

View Article and Find Full Text PDF

Objective: This study aimed to compare preoperative and postoperative measures in haemophiliacs who had simultaneous total hip and knee arthroplasties.

Methods: A retrospective database search identified five patients with severe factor 8 deficiencies who underwent simultaneous hip and knee joint replacement surgery between 2002-2018. Preoperative and postoperative evaluations included Harris Hip Score (HHS), Knee Society Score (KSS), Knee Injury and Osteoarthritis Outcome Score (KOOS), range of motion, flexion contracture (FC), Visual Analog Scale (VAS), hip-knee angle, and leg length discrepancy.

View Article and Find Full Text PDF

Synchrotron X-ray microtomography (S-µCT) is a highly valuable technique for investigating organ function and pathologies. However, its application is often limited by high radiation doses and the occurrence of ring artifacts. While S-µCT utilizing sparse-view projections can effectively decrease radiation doses, the reconstructed images frequently exhibit severe streaking artifacts, which are exacerbated by ring artifacts, ultimately compromising reconstruction accuracy, image quality, and resolution.

View Article and Find Full Text PDF

A dual pulse retrieval algorithm is introduced that builds upon time-domain interferometric strong-field ionization to simultaneously reconstruct both involved laser pulses in a waveform-resolved manner. The pulse characterization scheme removes many restrictions posed by former methods, leaving the avoidance of resonant ionization as a single boundary. It is widely and easily applicable at low cost and effort for common attosecond beamlines and allows for the robust and accurate in-situ retrieval of two unknown laser fields.

View Article and Find Full Text PDF

Creating durable, motion-compliant neural interfaces is crucial for accessing dynamic tissues under in vivo conditions and linking neural activity with behaviors. Utilizing the self-alignment of nano-fillers in a polymeric matrix under repetitive tension, here, we introduce conductive carbon nanotubes with high aspect ratios into semi-crystalline polyvinyl alcohol hydrogels, and create electrically anisotropic percolation pathways through cyclic stretching. The resulting anisotropic hydrogel fibers (diameter of 187 ± 13 µm) exhibit fatigue resistance (up to 20,000 cycles at 20% strain) with a stretchability of 64.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!