A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A heated humidifier does not reduce laryngo- pharyngeal complaints after brief laryngeal mask anesthesia. | LitMetric

A heated humidifier does not reduce laryngo- pharyngeal complaints after brief laryngeal mask anesthesia.

Can J Anaesth

Department of Anesthesiology and Pain Medicine, Konkuk University School of Medicine, 1 Hwayang-Dong, Gwanggin-Gu, Seoul, 143-701, Korea.

Published: February 2007

Purpose: Warming and humidification of inspired gases is standard care for intubated patients whose lungs are ventilated mechanically for prolonged periods. We examined whether active humidification of inspired gases might reduce laryngo-pharyngeal discomfort in patients undergoing brief laryngeal mask airway (LMA) anesthesia.

Methods: In a prospective trial, 200 adult patients undergoing elective surgery under general anesthesia were randomly assigned to receive ventilation without airway warming and exogenous humidification (Group C-control), or active warming and humidification of inspired gases (Group HUM-humidified), using a humidifier with a heated wire circuit. Inhalational anesthesia was maintained via a circle system. The temperatures and relative humidities of inspired gases were monitored continuously throughout surgery. Postoperative sore throat, dysphonia, and dysphagia were assessed one and 24 hr after anesthesia. Whenever symptoms were present, their severities were graded using a 101-point numerical rating scale.

Results: The mean temperature and relative humidity of the inspired gases in Group HUM were greater compared to Group C (36.1+/-0.4 degrees C and 99.5+/-0.5% vs 26.9+/-0.8 degrees C and 76.4+/-10.9%, respectively). Postoperatively, the overall frequencies of laryngeal and pharyngeal discomfort were similar in the two groups (53.8% and 54.9% in Group C vs 51.6% and 41.9% in Group HUM at one and 24 hr respectively, P>0.05). The groups were also similar with respect to the severity scores of laryngo-pharyngeal discomfort.

Conclusion: Active warming and humidification of inspired gases has no clinically appreciable effect in reducing the incidence and severity of laryngo-pharyngeal complaints after brief (

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF03022010DOI Listing

Publication Analysis

Top Keywords

inspired gases
24
humidification inspired
16
warming humidification
12
laryngeal mask
8
patients undergoing
8
active warming
8
gases group
8
group hum
8
inspired
6
gases
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!