Undersampled boundary pre-/postfilters for low bit-rate DCT-based block coders.

IEEE Trans Image Process

Department of Electrical Engineering and Electronics, The University of Liverpool, U.K.

Published: February 2007

It has been well established that critically sampled boundary pre-/postfiltering operators can improve the coding efficiency and mitigate blocking artifacts in traditional discrete cosine transform-based block coders at low bit rates. In these systems, both the prefilter and the postfilter are square matrices. This paper proposes to use undersampled boundary pre- and postfiltering modules, where the pre-/postfilters are rectangular matrices. Specifically, the prefilter is a "fat" matrix, while the postfilter is a "tall" one. In this way, the size of the prefiltered image is smaller than that of the original input image, which leads to improved compression performance and reduced computational complexities at low bit rates. The design and VLSI-friendly implementation of the undersampled pre-/postfilters are derived. Their relations to lapped transforms and filter banks are also presented. Two design examples are also included to demonstrate the validity of the theory. Furthermore, image coding results indicate that the proposed undersampled pre-/postfiltering systems yield excellent and stable performance in low bit-rate image coding.

Download full-text PDF

Source
http://dx.doi.org/10.1109/tip.2006.888344DOI Listing

Publication Analysis

Top Keywords

undersampled boundary
8
low bit-rate
8
block coders
8
low bit
8
bit rates
8
image coding
8
undersampled
4
boundary pre-/postfilters
4
low
4
pre-/postfilters low
4

Similar Publications

The earliest Miocene (Aquitanian, 23-20 Ma) remains a critically under-sampled 'dark age' in cetacean evolution. This is especially true of baleen whales (mysticetes), Aquitanian specimens of which remain almost entirely unknown. Across the globe, the nature of the cetacean fossil record radically shifts at the Oligocene-Miocene boundary, with mysticetes and some archaic odontocete lineages suddenly disappearing despite the availability of cetacean-bearing rock units.

View Article and Find Full Text PDF
Article Synopsis
  • Cardiac T2 mapping is a diagnostic tool that faces challenges with spatial resolution, which may limit its effectiveness in detecting small heart lesions.
  • This study presents a new cardiac T2 mapping technique using the SCC-LLRT algorithm, validated by tests on both phantoms and human participants, showing improved spatial resolution without increased acquisition time.
  • Results indicated that the new method significantly reduces artifacts and noise while enhancing overall image quality compared to traditional imaging techniques, leading to better-defined images of the myocardium.
View Article and Find Full Text PDF

This work develops and evaluates a self-navigated variable density spiral (VDS)-based manifold regularization scheme to prospectively improve dynamic speech magnetic resonance imaging (MRI) at 3 T. Short readout duration spirals (1.3-ms long) were used to minimize sensitivity to off-resonance.

View Article and Find Full Text PDF

Olympic Coast National Marine Sanctuary (OCNMS), which was established in 1994 and covers an area of 8257 km, is located along Washington State's remote and rugged outer coast towards the northernmost extent of the California Current System (CCS). In this region, summertime equatorward winds drive seasonal upwelling of cold, nutrient rich waters onto the continental shelf. These waters help fuel a highly diverse and productive ecosystem that includes marine mammal and seabird communities as well as commercially and culturally important fisheries.

View Article and Find Full Text PDF

High efficiency free-breathing 3D thoracic aorta vessel wall imaging using self-gating image reconstruction.

Magn Reson Imaging

April 2024

Paul C. Lauterbur Research Centre for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Science, Shenzhen, Guangdong, China. Electronic address:

Purpose: To improve the scan efficiency of thoracic aorta vessel wall imaging using a self-gating (SG)-based motion correction scheme.

Materials And Methods: A slab-selective variable-flip-angle 3D turbo spin-echo (SPACE) sequence was modified to acquire SG signals and imaging data. Cartesian sampling with a tiny golden-step spiral profile ordering was used to obtain the imaging data during the systolic period, and then the image data were subsequently corrected based on the SG signals and binned to different respiratory cycles.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!