A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Simultaneous determination of metabolic stability and identification of buspirone metabolites using multiple column fast liquid chromatography time-of-flight mass spectrometry. | LitMetric

Simultaneous determination of metabolic stability and identification of buspirone metabolites using multiple column fast liquid chromatography time-of-flight mass spectrometry.

J Chromatogr A

Agilent Technologies R&D and Marketing GmbH & Co. KG, Hewlett-Packard-Str. 8, 76337 Waldbronn, Germany.

Published: July 2007

AI Article Synopsis

  • The drug discovery process is shifting to conduct drug metabolism and pharmacokinetic (DMPK) studies earlier, allowing potential issues to be addressed alongside drug optimization.
  • Developing new assay methods for early adsorption, distribution, metabolism, and excretion (ADME) parameters like metabolic stability and metabolite identification is essential.
  • The study employs a fast two-column liquid chromatography (LC) method with a high-resolution ESI-TOF mass spectrometer to assess the metabolic stability and identify metabolites of buspirone in a single experiment.

Article Abstract

A recent trend in the drug discovery and development process is to shift the starting point of drug metabolism and pharmacokinetic (DMPK) studies to a time as early as possible in the development chain to address potential issues in parallel with the optimization of the drug's lead structure. Therefore, it is necessary to develop assay methods to determine early adsorption, distribution, metabolism and excretion (ADME) parameters like metabolic stability and metabolite identification. For metabolite identification it is of crucial importance to work with fast liquid chromatography/mass spectrometry (LC/MS) systems, which provide the necessary high throughput functionalities to handle a large number of samples in combination with high speed and high resolution chromatography as well as mass accuracy. In this study a fast two-column liquid chromatography (LC) method will be used to simultaneously determine metabolic stability and to identify metabolites of buspirone using highly accurate mass measurement by means of an electrospray time-of-flight (ESI-TOF) mass spectrometer. Whereby, the metabolic stability will be determined on a short sub-two micron column, the main metabolites will be identified in the same experiment by the automated use of a long sub-two micron column, which provides the necessary high resolution.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2007.01.024DOI Listing

Publication Analysis

Top Keywords

metabolic stability
16
fast liquid
8
liquid chromatography
8
metabolite identification
8
high resolution
8
sub-two micron
8
micron column
8
simultaneous determination
4
metabolic
4
determination metabolic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!