Objective: To evaluate the sensitivity to change of power Doppler ultrasound (PDUS) assessment of joint inflammation and the predictive value of PDUS parameters in disease activity and radiologic outcome in patients with early rheumatoid arthritis (RA).

Methods: Forty-two patients with early RA who started therapy with disease-modifying antirheumatic drugs underwent blinded sequential clinical, laboratory, and ultrasound assessment at baseline, 3 months, 6 months, and 1 year and radiographic assessment at baseline and 1 year. For each patient, 28-joint Disease Activity Score (DAS28) was recorded at each visit. The presence of synovitis was investigated in 28 joints using gray-scale ultrasonography and intraarticular power Doppler signal. Active synovitis was defined as intraarticular synovitis detected with power Doppler signal. The ultrasound joint count for active synovitis and an overall joint index for power Doppler signal were calculated. Sensitivity to change of PDUS variables was assessed by estimating the smallest detectable difference (SDD) from the intraobserver variability.

Results: The SDD for ultrasound joint count for active synovitis and ultrasound joint index for power Doppler signal was lower than mean changes from baseline to 3 months, 6 months, and 1 year. Time-integrated values of PDUS parameters demonstrated a highly significant correlation with DAS28 after 1 year (r = 0.63, P < 0.001) and a stronger correlation with radiographic progression (r = 0.59-0.66, P < 0.001) than clinical and laboratory parameters (r < 0.5).

Conclusion: PDUS is a sensitive and reliable method for longitudinal assessment of inflammatory activity in early RA. PDUS findings may have a predictive value in disease activity and radiographic outcome.

Download full-text PDF

Source
http://dx.doi.org/10.1002/art.22461DOI Listing

Publication Analysis

Top Keywords

power doppler
24
disease activity
16
doppler signal
16
active synovitis
12
ultrasound joint
12
assessment joint
8
inflammatory activity
8
activity early
8
early rheumatoid
8
rheumatoid arthritis
8

Similar Publications

The maternal body mass index and first-trimester placental (vascular) development.

Placenta

December 2024

Department of Obstetrics and Gynecology, Erasmus MC, University Medical Center, Rotterdam, the Netherlands. Electronic address:

Background: Maternal obesity is associated with maternal complications, including hypertensive disorders of pregnancy (HDP), and related fetal complications, such as fetal growth restriction. During pregnancy, the placenta is one of the key regulators of embryonic and fetal growth. Previous studies mainly investigated placental growth by measuring postpartum placental weight.

View Article and Find Full Text PDF

The predictive value of anti-IFI16 antibodies for the development or persistence of digital ulcers in systemic sclerosis.

Clin Rheumatol

January 2025

Department of Rheumatology, Huashan Hospital, Fudan University, No.12 Wulumuqi Zhong Road, Shanghai, 200040, China.

To evaluate the association of anti-IFI16 antibodies with peripheral vasculopathy and the predictive value of anti-IFI16 antibodies for the development or persistence of digital ulcers (DPDU) in SSc. A total of 42 SSc patients and 42 age- and sex-matched healthy controls were enrolled. Anti-IFI16 antibodies were examined by ELISA.

View Article and Find Full Text PDF

Usefulness of Aortic Valve Calcification in Patients With Low-Flow Aortic Stenosis.

Circ Cardiovasc Imaging

January 2025

Department of Cardiology, Odense University Hospital, Denmark (N.S.B.M., J.S.D., M.A., A.H., R.C.-S., J.E.M., K.A.Ø., M.-A.C.).

Background: Aortic valve calcification (AVC) has been shown to be a powerful assessment of aortic stenosis (AS) severity and a predictor of adverse outcomes. However, its accuracy in patients with low-flow AS has not yet been proven. The objective of the study was to assess the predictive value of AVC in patients with classical low-flow (CLF, that is, low-flow reduced left ventricular ejection fraction) or paradoxical low-flow (PLF, that is, low-flow preserved left ventricular ejection fraction) AS.

View Article and Find Full Text PDF

UAV Trajectory Control and Power Optimization for Low-Latency C-V2X Communications in a Federated Learning Environment.

Sensors (Basel)

December 2024

Department of Electrical, Computer and Biomedical Engineering, Toronto Metropolitan University, Toronto, ON M5B2K3, Canada.

Unmanned aerial vehicle (UAV)-enabled vehicular communications in the sixth generation (6G) are characterized by line-of-sight (LoS) and dynamically varying channel conditions. However, the presence of obstacles in the LoS path leads to shadowed fading environments. In UAV-assisted cellular vehicle-to-everything (C-V2X) communication, vehicle and UAV mobility and shadowing adversely impact latency and throughput.

View Article and Find Full Text PDF

Objective: The study aimed to explore the utility of contrast-enhanced ultrasound (CEUS) as a tool for detecting minimal inflammation in rheumatoid arthritis (RA) patients in sustained remission (SR) and to correlate the findings with Disease Activity Score 28 (DAS28) status scores and various ultrasound (US) scores.

Patients And Methods: Thirty RA patients in SR (minimum 6 months), 12 with active disease, and 10 healthy controls were included. Clinical evaluations and US assessments were performed, including grayscale US (GSUS), power Doppler US (PDUS), and Global OMERACT-EULAR Synovitis Score (GLOESS).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!