Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Implant and reimplantation surgery should be carried out with preservation of residual hearing. The aim of this study is to evaluate the effects of such a surgery on hearing threshold. We report the results on 40 patients, 20 males and 20 females, aged between 5 and 70 (mean 29) years, 16 pre-verbal and 24 post-verbal, with measurable pre-operative auditory thresholds. We used the following implants: Advanced Bionics, Med-El, Cochlear, and MXM Digisonic. Four of the patients underwent cochlear reimplantation owing to device failure. A complete insertion was obtained in all patients. Responses to pure-tone stimuli were evaluated in each ear in pre-implant conditions and 3 months after cochlear implant or reimplantation. The explantation was performed with minimal cochlear trauma and preservation of the explanted electrode integrity. 35% showed no change of the hearing threshold, 45% showed a slight worsening of the hearing threshold level in the implanted ear, and 20% had a total loss of residual hearing. Median increases of threshold levels were 10, 5, 10 and 3 dB HL respectively for 125, 250, 500 and 1 kHz. In the group of 4 patients who underwent cochlear reimplantation, 2 showed no variation of the hearing threshold, 1 preserved an appreciable hearing threshold, and 1 had a total loss of residual hearing. The data seem to suggest that hearing function is rather resistant to mechanical trauma during implant and reimplant surgery; the authors hypothesize a role for direct spiral ganglion activation under intense mechanical stimulation.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1159/000099019 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!