A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical condition at mid-to-late follow-up after transatrial-transpulmonary repair of tetralogy of Fallot. | LitMetric

Objectives: To assess the clinical condition at mid-to-late follow-up in tetralogy of Fallot corrected by a transatrial-transpulmonary approach at a young age and to identify risk factors associated with right ventricular dilation/dysfunction and with decreased exercise tolerance.

Methods: Patients with tetralogy of Fallot underwent cardiac magnetic resonance imaging, maximal bicycle ergometry, electrocardiography, Holter monitoring, and spirometry. Multivariate linear regression analyses were used to determine independent predictors for selected clinical parameters.

Results: Fifty-nine patients (mean +/- SD), age at repair 0.9 +/- 0.5 years, interval since repair 14 +/- 5 years, were included. The median pulmonary regurgitant fraction was 32% (0%-57%). Compared with published data on healthy controls, Fallot patients had significantly larger right ventricular end-diastolic and end-systolic volumes and smaller right ventricular and left ventricular ejection fractions. Maximum oxygen consumption was 97% +/- 17% and maximum workload 89% +/- 13% of predicted. Median QRS duration was 110 ms (82-161 ms). No important ventricular arrhythmias were found. Compared with patients without a transannular patch, patients with a patch had more pulmonary regurgitation, a larger right ventricle, worse right ventricular and left ventricular ejection fractions, but comparable exercise capacity. Multivariate regression analysis identified the following independent determinants for larger right ventricular volumes: longer interval since repair, longer QRS duration, and higher pulmonary regurgitation percentage. The following were independent determinants for smaller right ventricular ejection fraction: abnormal right ventricular outflow tract wall motion, longer interval since repair, and longer QRS duration. For smaller maximum oxygen consumption, the independent determinants were smaller right ventricular ejection fraction and longer QRS duration.

Conclusions: At mid-to-late follow-up, clinical condition in tetralogy of Fallot corrected according to contemporary surgical approaches appears well preserved. However, even these patients show right ventricular dilation and dysfunction associated with impaired functional capacity. Abnormalities relate to right ventricular outflow tract motion abnormalities, longer interval since repair, longer QRS duration, and more severe pulmonary regurgitation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jtcvs.2006.10.022DOI Listing

Publication Analysis

Top Keywords

tetralogy fallot
16
interval repair
16
ventricular ejection
16
qrs duration
16
longer qrs
16
ventricular
13
clinical condition
12
mid-to-late follow-up
12
smaller ventricular
12
pulmonary regurgitation
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!