Qualind: A method for assessing the accuracy of automated tests.

J Am Acad Audiol

Department of Otolaryngology, University of Minnesota, Minneapolis, Minnesota 55455, USA.

Published: January 2007

As audiology strives for cost containment, standardization, accuracy of tests, and accountability, greater use of automated tests is likely. Highly skilled audiologists employ quality control factors that contribute to test accuracy, but they are not formally included in test protocols, resulting in a wide range of accuracy, owing to the various skill and experience levels of clinicians. A method that incorporates validated quality indicators may increase accuracy and enhance access to accurate hearing tests. This report describes a quality assessment method that can be applied to any test that (1) requires behavioral or physiologic responses, (2) is associated with factors that correlate with accuracy, and (3) has an available independent measure of the dimension being assessed, including tests of sensory sensitivity, cognitive function, aptitude, academic achievement, and personality. In this report the method is applied to AMTAS, an automated method for diagnostic pure-tone audiometry.

Download full-text PDF

Source
http://dx.doi.org/10.3766/jaaa.18.1.7DOI Listing

Publication Analysis

Top Keywords

automated tests
8
method applied
8
accuracy
6
tests
5
qualind method
4
method assessing
4
assessing accuracy
4
accuracy automated
4
tests audiology
4
audiology strives
4

Similar Publications

Contrast-enhanced ultrasound-based AI model for multi-classification of focal liver lesions.

J Hepatol

January 2025

CAS Key Laboratory of Molecular Imaging, Institute of Automation, Chinese Academy of Sciences, Beijing, China; School of Artificial Intelligence, University of Chinese Academy of Sciences, Beijing, China. Electronic address:

Background & Aims: Accurate multi-classification is the prerequisite for reasonable management of focal liver lesions (FLLs). Ultrasound is the common image examination, but lacks accuracy. Contrast enhanced ultrasound (CEUS) offers better performance, but highly relies on experience.

View Article and Find Full Text PDF

A novel hybrid ViT-LSTM model with explainable AI for brain stroke detection and classification in CT images: A case study of Rajshahi region.

Comput Biol Med

January 2025

Department of Biomedical Engineering, Islamic University, Kushtia, 7003, Bangladesh; Bio-Imaging Research Laboratory, Islamic University, Kushtia, 7003, Bangladesh. Electronic address:

Computed tomography (CT) scans play a key role in the diagnosis of stroke, a leading cause of morbidity and mortality worldwide. However, interpreting these scans is often challenging, necessitating automated solutions for timely and accurate diagnosis. This research proposed a novel hybrid model that integrates a Vision Transformer (ViT) and a Long Short Term Memory (LSTM) to accurately detect and classify stroke characteristics using CT images.

View Article and Find Full Text PDF

This study explored the evolving landscape of Microphysiological Systems (MPS), with a focus on organoids and organ-on-a-chip (OoC) technologies, which are promising alternatives to animal testing in drug discovery. MPS technology offers in vitro models with high physiological relevance, simulating organ function for pharmacokinetic studies. Organoids composed of 3D cell aggregates and OoCs mimicking in vivo environments based on microfluidic platforms represent the forefront of MPS.

View Article and Find Full Text PDF

Investigation of the threonine metabolism of Echinococcus multilocularis: The threonine dehydrogenase as a potential drug target in alveolar echinococcosis.

Int J Parasitol Drugs Drug Resist

January 2025

Institute of Parasitology, Vetsuisse Faculty, University of Bern, Bern, Switzerland; Multidisciplinary Center for Infectious Diseases, University of Bern, Bern, Switzerland. Electronic address:

Alveolar echinococcosis (AE) is a severe zoonotic disease caused by the metacestode stage of the fox tapeworm Echinococcus multilocularis. We recently showed that E. multilocularis metacestode vesicles scavenge large amounts of L-threonine from the culture medium.

View Article and Find Full Text PDF

Free-Breathing Respiratory Triggered High-Pitch Lung CT: Insights From Phantom and Patient Scans.

Invest Radiol

January 2025

From the Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany (A. Schwarz, A. Simon, A.M.); Siemens Healthineers AG, Forchheim, Germany (A. Schwarz, C.H., J.D., A. Simon); Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany (F.K.W., S.G., M.S.); and Institut for Radiology, Pediatric and Neuroradiology, Helios Hospital, Schwerin, Germany (H.-J.R.).

Objective: Respiratory motion can affect image quality and thus affect the diagnostic accuracy of CT images by masking or mimicking relevant lung pathologies. CT examinations are often performed during deep inspiration and breath-hold to achieve optimal image quality. However, this can be challenging for certain patient groups, such as children, the elderly, or sedated patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!