A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of optical low-coherence reflectometry and ultrasound pachymetry in measuring corneal graft thickness. | LitMetric

Purpose: To compare optical low-coherence reflectometry (OLCR) and ultrasound pachymetry in measuring corneal graft thickness in patients after keratoplasty.

Methods: We retrospectively measured the central graft thickness in 41 eyes of 41 patients with the OLCR pachymeter (Haag Streit, Koeniz, Switzerland) and the SP-2000 contact ultrasound pachymeter (Tomey, Nagoya, Japan). Five separate measurements were performed on each eye with both methods. Mean, SD, repeatability, and coefficient of variation of measurements were calculated, and the correlation between the 2 methods was studied with Spearman regression.

Results: Mean central graft thickness was 546 +/- 51 (SD) microm with the contact ultrasound pachymeter and 546 +/- 47 microm with the OLCR pachymeter. The correlation between both methods was strong (rs = 0.96). No significant differences in mean SD of measurements were observed between OLCR pachymetry (mean SD = 4.66 microm) and contact ultrasound pachymetry (mean SD = 4.88 microm). The repeatability of both methods was comparable (P = 0.06) and high (the average coefficient of variation of the central corneal graft thickness was 0.9% with both pachymeters). The postoperative time did not affect the correlation between both pachymeters (P > 0.05).

Conclusions: Central corneal graft thickness values obtained with the OLCR pachymeter were similar to those obtained with a contact ultrasound pachymeter. In some cases of lamellar keratoplasty, the corneal refractive index could change at the interface level that could affect OLCR measurements.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.ico.0000248387.62637.12DOI Listing

Publication Analysis

Top Keywords

graft thickness
24
corneal graft
16
contact ultrasound
16
ultrasound pachymetry
12
olcr pachymeter
12
ultrasound pachymeter
12
optical low-coherence
8
low-coherence reflectometry
8
pachymetry measuring
8
measuring corneal
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!