In January 2004, two EUROMET supplementary comparisons started, coordinated by Physikalisch-Technische Bundesanstalt (PTB): one for the radiation protection quantity 'personal dose equivalent' Hp(10) using X-radiation, and one for the quantity 'absorbed dose in tissue' Dt(0.07) using beta reference fields. The focus of both comparisons lies on calibrations using radiation qualities at which the dissemination of the quantities considered here is difficult. Within the scope of the two comparisons, an ionisation chamber shall be calibrated. Together with a transfer chamber optimised to measure Hp(10) and Dt(0.07), respectively, for each comparison a complete electronic measuring system is circulated. These transfer devices, as well as, a specially developed test procedure, which has to be carried out by each participant to check the instruments, are described. For both comparisons, the results of those participants who had finished their measurements and delivered the measuring protocol until February 2005 were evaluated. As the comparisons are still running these first results are shown in an anonymous form. A first assessment of the data will be given.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncl530DOI Listing

Publication Analysis

Top Keywords

euromet supplementary
8
supplementary comparisons
8
comparisons
6
comparisons photon
4
photon beta
4
beta radiation--actual
4
radiation--actual state
4
state january
4
january 2004
4
2004 euromet
4

Similar Publications

EUROMET supplementary comparisons for photon and beta radiation--actual state and first results.

Radiat Prot Dosimetry

September 2008

Physikalisch-Technische Bundesanstalt Bundesallee 100, 38116 Braunschweig, Germany.

In January 2004, two EUROMET supplementary comparisons started, coordinated by Physikalisch-Technische Bundesanstalt (PTB): one for the radiation protection quantity 'personal dose equivalent' Hp(10) using X-radiation, and one for the quantity 'absorbed dose in tissue' Dt(0.07) using beta reference fields. The focus of both comparisons lies on calibrations using radiation qualities at which the dissemination of the quantities considered here is difficult.

View Article and Find Full Text PDF

Radon activity concentration--a Euromet and BIPM supplementary comparison.

Appl Radiat Isot

November 2006

Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany.

For the first time, a comparison of radon activity concentration in air has been performed within the scope of Euromet. In the project 657, 'Comparison of calibration facilities for the radon activity concentration,' 12 participants from 9 countries compared different radon reference atmospheres at 1, 3 and 10 k Bq m-3 via a transfer standard. The comparison was listed as BIPM supplementary comparison EUROMET.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!