A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Hyperpolarized 83Kr and 129Xe NMR relaxation measurements of hydrated surfaces: implications for materials science and pulmonary diagnostics. | LitMetric

In this proof of principle work, a technique is introduced to study hydrated surfaces using hyperpolarized (hp) 83Kr NMR spectroscopy. The longitudinal (T1) relaxation of hp-83Kr is shown to be extremely sensitive to the presence of adsorbed water on hydrophilic borosilicate and hydrophobic siliconized glass surfaces. The krypton surface relaxation is found to be largely independent of the total gas pressure applied to the studied materials, and the presented technique is therefore fairly robust. However, the relaxational properties of hp-83Kr can be "tuned" by adjusting the composition of the optical pumping gas mixture. This effect may be important for practical applications such as hp-83Kr MR imaging and can be achieved without sacrificing signal intensity. Complementary information to that of hp-83Kr surface relaxation data can be obtained from hp-129Xe relaxation measurements that are sensitive to the presence of paramagnetic surface sites. In contrast to the signal decay of hp-129Xe, the longitudinal relaxation of 83Kr is largely unaffected by paramagnetic impurities, and in some materials, 83Kr and 129Xe show comparable T1 times that are caused by two completely different relaxation mechanisms. Finally, the relaxation times of 83Kr in contact with bovine lung surfactant coated glass pores that are similar in size to mammalian alveoli are presented. The results suggest that in vivo MR studies may be feasible and could provide valuable information about changes in pulmonary surface chemistry.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ja065994tDOI Listing

Publication Analysis

Top Keywords

hyperpolarized 83kr
8
83kr 129xe
8
relaxation
8
relaxation measurements
8
hydrated surfaces
8
longitudinal relaxation
8
sensitive presence
8
surface relaxation
8
129xe nmr
4
nmr relaxation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!