Purpose: The goal of the present study was to evaluate the reproducibility of cerebral A1 adenosine receptor (A1AR) quantification using [18F]CPFPX and PET in a test-retest design.

Methods: Eleven healthy volunteers were studied twice. Eight brain regions ranging from high to low receptor binding were examined. [18F]CPFPX was injected as a bolus with subsequent infusion over 120 min. Various outcome parameters were compared based on either metabolite-corrected venous blood sampling [e.g. apparent equilibrium total distribution volume (DVt')] or a reference region [ratio of specific to non-specific distribution volume (BP2)].

Results: Test-retest variability was low in the outcome measure BP2 (on average 5.9%) and moderate in DVt' (on average 13.2%). Regarding reproducibility, the outcome parameter BP2 showed an intra-class correlation coefficient (ICC) of 0.94 +/- 0.1. For DVt' the between-subject coefficient of variation (%CV) was similar to the within-subject %CV (around 10%), resulting in a poor ICC of 0.06 +/- 0.2.

Conclusion: Our results suggest that quantification of [18F]CPFPX imaging is reproducible and reliable for PET studies of the cerebral A1AR. Among the outcome parameters the non-invasive measures were of superior test-retest stability over the invasive.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00259-006-0309-xDOI Listing

Publication Analysis

Top Keywords

quantification [18f]cpfpx
12
test-retest stability
8
cerebral adenosine
8
adenosine receptor
8
[18f]cpfpx pet
8
outcome parameters
8
distribution volume
8
test-retest
4
stability cerebral
4
receptor quantification
4

Similar Publications

Validation of analytical HPLC with post-column injection as a method for rapid and precise quantification of radiochemical yields.

J Chromatogr B Analyt Technol Biomed Life Sci

August 2023

Forschungszentrum Jülich GmbH, Institute of Neurosciences and Medicine, Nuclear Chemistry (INM-5), Wilhelm-Johnen-Str., 52428 Jülich, Germany; Institute of Radiochemistry and Experimental Molecular Imaging, Faculty of Medicine and University Hospital Cologne, University of Cologne, Kerpener Str. 62, 50937 Cologne, Germany. Electronic address:

Accurate assessment of isolated radiochemical yields (RCYs) is a prerequisite for efficient and reliable optimization of labeling reactions. In practice, radiochemical conversions (RCCs) determined by HPLC analysis of crude reaction mixtures are often used to estimate RCYs. However, incomplete recovery of radioactivity from the stationary phase can lead to significant inaccuracies if RCCs are calculated based on the activity eluted from the column (i.

View Article and Find Full Text PDF

Image-Derived Input Functions for Quantification of A Adenosine Receptors Availability in Mice Brains Using PET and [F]CPFPX.

Front Physiol

January 2020

Institut für Neurowissenschaften und Medizin (INM-2), Forschungszentrum Jülich, Jülich, Germany.

Purpose: imaging for the A adenosine receptors (AARs) with positron emission tomography (PET) using 8-cyclopentyl-3-(3-[F]fluoropropyl)-1-propylxan- thine ([F]CPFPX) has become an important tool for studying physiological processes quantitatively in mice. However, the measurement of arterial input functions (AIFs) on mice is a method with restricted applicability because of the small total blood volume and the related difficulties in withdrawing blood. Therefore, the aim of this study was to extract an appropriate [F]CPFPX image-derived input function (IDIF) from dynamic PET images of mice.

View Article and Find Full Text PDF

Influence of binding affinity and blood plasma level on cerebral pharmacokinetics and PET imaging characteristics of two novel xanthine PET radioligands for the A adenosine receptor.

Nucl Med Biol

May 2021

Institute of Neuroscience and Medicine - Molecular Organization of the Brain (INM-2), Forschungszentrum Jülich GmbH, 52428 Jülich, Germany; Neurological Department, Medical Faculty, Heinrich-Heine-University, Universitätsstraße 1, 40225 Düsseldorf, Germany.

Introduction: The suitability of novel positron emission tomography (PET) radioligands for quantitative in vivo imaging is affected by various physicochemical and pharmacological parameters. In this study, the combined effect of binding affinity, lipophilicity, protein binding and blood plasma level on cerebral pharmacokinetics and PET imaging characteristics of three xanthine-derived A adenosine receptor (AAR) radioligands was investigated in rats.

Methods: A comparative evaluation of two novel cyclobutyl-substituted xanthine derivatives, 8-cyclobutyl-3-(3-[F]fluoropropyl)-1-propylxanthine ([F]CBX) and 3-(3-[F]fluoropropyl)-8-(1-methylcyclobutyl)-1-propylxanthine ([F]MCBX), with the reference AAR radioligand 8-cyclopentyl-3-(3-[F]fluoropropyl)-1-propylxanthine ([F]CPFPX) was conducted.

View Article and Find Full Text PDF

Purpose: The A1AR antagonist 8-cyclopentyl-3-(3-fluoropropyl)-1-propylxanthine ([(18)F]CPFPX) has recently been shown to be a suitable radiotracer for quantitative in vivo imaging of the A1 adenosine receptor (A1AR) in rats. The present study evaluates the reproducibility of non-invasive longitudinal A1AR studies with [(18)F]CPFPX and a dedicated small animal positron emission tomography (PET) scanner.

Procedures: Twelve male Sprague Dawley rats underwent four repeated dynamic PET scans with a bolus injection of [(18)F]CPFPX.

View Article and Find Full Text PDF

Unlabelled: In vivo imaging of the A1 adenosine receptor (A1AR) using (18)F-8-cyclopentyl-3-(3-fluoropropyl)-1-propylxanthine ((18)F-CPFPX) and PET has become an important tool for studying physiologic and pathologic states of the human brain. However, dedicated experimental settings for small-animal studies are still lacking. The aim of the present study was therefore to develop and evaluate suitable pharmacokinetic models for the quantification of the cerebral A1AR in high-resolution PET.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!