Mechanical heart valve performance in a pulsatile pediatric ventricular assist device.

ASAIO J

Division of Artificial Organs, Department of Surgery, Penn State College of Medicine, Penn State Milton S. Hershey Medical Center, Hershey, Pennsylvania 17033, USA.

Published: February 2007

A pulsatile pediatric ventricular assist device with a dynamic stroke volume of 12 ml is currently under development at the Pennsylvania State University. A monoleaflet valve (Björk-Shiley Monostrut) and a bileaflet valve (CPHV, CarboMedics Prosthetic Heart Valve) were examined in this study. A high-speed video and data acquisition system was used to simultaneously record video images, pressure waveforms, and flow waveforms for an array of in vitro test conditions that varied heart rate and systolic duration. The CPHV in both the horizontal and vertical orientations have larger regurgitant volumes than the Monostrut valves at all operating conditions in both the inlet and outlet positions. However, the CPHV has higher stroke volumes and cardiac outputs than the Monostrut valve at higher heart rates and longer systolic durations. In addition, the hydrodynamic performance of the Monostrut valve is more sensitive to changes in operating conditions for the pulsatile pediatric ventricular assist device than the CPHV in both orientations. Additional testing is under way to identify the optimal operating conditions for each type of valve.

Download full-text PDF

Source
http://dx.doi.org/10.1097/01.mat.0000247959.37562.0aDOI Listing

Publication Analysis

Top Keywords

pulsatile pediatric
12
pediatric ventricular
12
ventricular assist
12
assist device
12
operating conditions
12
heart valve
8
monostrut valve
8
valve
7
mechanical heart
4
valve performance
4

Similar Publications

: Although preeclampsia (PE) and small for gestational age (SGA) are known to come from impaired placentation during the first trimester, prior studies have focused mostly on Doppler findings in the second trimester. : In this retrospective pilot study, we enrolled 628 singleton pregnant women who underwent ultrasound in both the first and second trimesters and blood test. For SGA correlation, we further excluded 12 subjects with PE because PE may be the cause of SGA.

View Article and Find Full Text PDF

Background: The Advanced Cardiac Therapies Improving Outcomes Network (ACTION) began in 2018 as a collaborative learning health system committed to improving outcomes in pediatric heart failure, including children and adults with congenital heart disease, supported with ventricular assist devices (VADs). This report describes patient and device characteristics, and outcomes through 1-year post-implant.

Methods: The ACTION VAD registry report was created from data submitted to the ACTION learning network from April 2018 to June 2023.

View Article and Find Full Text PDF

Background: The Pediatric Interagency Registry for Mechanical Circulatory Support (Pedimacs), supported by The Society of Thoracic Surgeons, provides detailed information on pediatric patients supported with ventricular assist devices (VADs).

Methods: From September 19, 2012, to December 31, 2023, there were 1648 devices in 1349 patients (<19 years) from 39 North American Hospitals with 100 patients enrolled in 2023.

Results: Cardiomyopathy was the most common underlying etiology (59%), followed by congenital heart disease (26%) and myocarditis (8%).

View Article and Find Full Text PDF

Long-acting growth hormones (LAGHs) represent a significant advancement in the treatment of pediatric growth hormone deficiency (GHD), offering an alternative to daily recombinant human growth hormone (rhGH) therapy. Traditional rhGH treatments, while effective, require daily injections, often leading to poor adherence due to the frequency of dosing, injection pain, and difficulties with storage and travel. In contrast, LAGHs, such as somatrogon, somapacitan, and lonapegsomatropin, are designed for once-weekly administration, improving patient compliance and quality of life.

View Article and Find Full Text PDF

This study aimed to analyze the relationship between cutaneous microcirculation reactivity, retinal circulation, macrocirculation function, and specific adhesion molecules in young patients with uncomplicated type 1 diabetes. Fifty-five patients with type 1 diabetes mellitus (T1DM), aged 8 to 18 years, were divided into subgroups based on skin microcirculation reactivity. The cutaneous microcirculatory vessels were considered reactive if post-test PORH coverage increased compared to pre-test coverage.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!