Proton magnetic resonance spectroscopy ((1)H-MRS) provides specific metabolic information not otherwise observable by any other imaging method. (1)H-MRS of the brain at 3 T is a new tool in the modern neuroradiological armamentarium whose main advantages, with respect to the well-established and technologically advanced 1.5-T (1)H-MRS, include a higher signal-to-noise ratio, with a consequent increase in spatial and temporal resolutions, and better spectral resolution. These advantages allow the acquisition of higher quality and more easily quantifiable spectra in smaller voxels and/or in shorter times, and increase the sensitivity in metabolite detection. However, these advantages may be hampered by intrinsic field-dependent technical issues, such as decreased T(2) signal, chemical shift dispersion errors, J-modulation anomalies, increased magnetic susceptibility, eddy current artifacts, challenges in designing and obtaining appropriate radiofrequency coils, magnetic field instability and safety hazards. All these limitations have been tackled by manufacturers and researchers and have received one or more solutions. Furthermore, advanced (1)H-MRS techniques, such as specific spectral editing, fast (1)H-MRS imaging and diffusion tensor (1)H-MRS imaging, have been successfully implemented at 3 T. However, easier and more robust implementations of these techniques are still needed before they can become more widely used and undertake most of the clinical and research (1)H-MRS applications.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00330-006-0546-1 | DOI Listing |
Int J Mol Sci
January 2025
Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104, USA.
Radiation therapy (RT) is the cornerstone treatment for prostate cancer; however, it frequently induces gastrointestinal and genitourinary toxicities that substantially diminish the patients' quality of life. While many individuals experience transient side effects, a subset endures persistent, long-term complications. A promising strategy to mitigate these toxicities involves enhancing tumor radiosensitivity, potentially allowing for lower radiation doses.
View Article and Find Full Text PDFNMR Biomed
March 2025
Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania, USA.
The purpose of this study was to measure T and T relaxation times of NAD proton resonances in the downfield H MRS spectrum in human brain at 7 T in vivo and to assess the propagation of relaxation time uncertainty in NAD quantification. Downfield spectra from eight healthy volunteers were acquired at multiple echo times to measure T relaxation times, and saturation recovery data were acquired to measure T relaxation times. The downfield acquisition used a spectrally selective 90° sinc pulse for excitation centered at 9.
View Article and Find Full Text PDFEur J Radiol
January 2025
MR-Unit, Dept. Diagnostic and Interventional Radiology, Institute for Clinical and Experimental Medicine, Videnska 1958/9, 140 21 Prague 4, Czech Republic.
Purpose: This prospective pilot study aims to evaluate the capabilities of novel quantitative ultrasound (QUS) methods based on attenuation (Att.PLUS) and sound speed (SSp.PLUS) for detecting liver fat.
View Article and Find Full Text PDFAdv Sci (Weinh)
January 2025
Key Laboratory of Magnetic Resonance in Biological Systems, State Key Laboratory of Magnetic Resonance Spectroscopy and Imaging, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics, Huazhong University of Science and Technology, Wuhan, 430071, China.
Magnetic resonance imaging (MRI) is a cornerstone technology in clinical diagnostics and in vivo research, offering unparalleled visualization capabilities. Despite significant advancements in the past century, traditional H MRI still faces sensitivity limitations that hinder its further development. To overcome this challenge, hyperpolarization methods have been introduced, disrupting the thermal equilibrium of nuclear spins and leading to an increased proportion of hyperpolarized spins, thereby enhancing sensitivity by hundreds to tens of thousands of times.
View Article and Find Full Text PDFJ Magn Reson Imaging
January 2025
Developing Brain Institute, Children's National Hospital, Washington, D.C., USA.
The biochemical composition and structure of the brain are in a rapid change during the exuberant stage of fetal and neonatal development. H-MRS is a noninvasive tool that can evaluate brain metabolites in healthy fetuses and infants as well as those with neurological diseases. This review aims to provide readers with an understanding of 1) the basic principles and technical considerations relevant to H-MRS in the fetal-neonatal brain and 2) the role of H-MRS in early fetal-neonatal development brain research.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!