Aims: To examine the visual outcome and identify risk factors for postoperative uveitis, macular oedema and neodymium-doped yttrium aluminium garnet (Nd:YAG) capsulotomy after phacoemulsification and intraocular lens (IOL) implantation in patients with uveitis.

Method: This is a retrospective review of the medical records of 101 eyes of 101 patients. One eye was randomly selected for inclusion in patients who had bilateral surgery. Patients with juvenile arthritis, keratouveitis and lymphoma-associated uveitis were excluded.

Results: At the first postoperative and final visits, visual acuity was significantly better (p<0.001), and 64.4% and 71.3% of patients, respectively, had achieved >or=2 Snellen's lines of visual improvement. The cumulative probability of doubling of the visual angle was 52% over 6 years of follow-up, and this occurred at a higher rate in the presence of preoperative retinal or optic nerve lesions (HR (95% CI) 4.49 (1.41 to 14.29)). Within 3 months after operation, uveitis was more likely to develop in female patients (OR (95% CI) 6.21 (1.41 to 27.43)) and in the presence of significant intraoperative posterior synechiae (OR (95% CI) 8.43 (1.09 to 65.41)); macular oedema was more likely to develop in patients who developed postoperative uveitis (OR (95% CI) 7.45 (1.63 to 34.16)). Nd:YAG capsulotomy occurred at a higher rate in patients aged
Conclusion: Most patients with uveitis achieve improved visual acuity after phacoemulsification, but an increasing rate of visual loss is observed in those with pre-existent macular or optic nerve lesions. Identifying patients who are at risk of postoperative complications should help in patient counselling and to pre-empt these complications by using preoperative prophylactic corticosteroids, careful IOL selection and postoperative intensive corticosteroids.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1955648PMC
http://dx.doi.org/10.1136/bjo.2007.114801DOI Listing

Publication Analysis

Top Keywords

patients
8
postoperative uveitis
8
macular oedema
8
ndyag capsulotomy
8
occurred higher
8
higher rate
8
uveitis
5
outcome phacoemulsification
4
phacoemulsification patients
4
patients uveitis
4

Similar Publications

Importance: States have implemented multiple policies likely to influence opioid prescribing; few national general population studies examine those policies' effects on per-capita opioid morphine milligram equivalents (MME) dispensed.

Objective: To examine state policies' effects on opioids per-capita MMEs dispensed at retail pharmacies.

Design: A longitudinal study of associations between MME per capita and implementation of policy interventions at different times across states.

View Article and Find Full Text PDF

Deep Equilibrium Unfolding Learning for Noise Estimation and Removal in Optical Molecular Imaging.

Comput Med Imaging Graph

January 2025

CAS Key Laboratory of Molecular Imaging, Institute of Automation, Chinese Academy of Sciences, Beijing 100190, China; School of Artificial Intelligence, University of Chinese Academy of Sciences, Beijing 100049, China; National Key Laboratory of Kidney Diseases, Beijing 100853, China. Electronic address:

In clinical optical molecular imaging, the need for real-time high frame rates and low excitation doses to ensure patient safety inherently increases susceptibility to detection noise. Faced with the challenge of image degradation caused by severe noise, image denoising is essential for mitigating the trade-off between acquisition cost and image quality. However, prevailing deep learning methods exhibit uncontrollable and suboptimal performance with limited interpretability, primarily due to neglecting underlying physical model and frequency information.

View Article and Find Full Text PDF

Feasibility of very low iodine dose aortoiliac CT angiography using dual-source photon-counting detector CT.

Eur J Radiol

January 2025

Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:

Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.

Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.

View Article and Find Full Text PDF

Feasibility of on-site CT-FFR analysis on cardiac photon-counting CT in evaluation of hemodynamically significant stenosis in comparison to invasive catheter angiography.

Eur J Radiol

January 2025

Department of Radiology and Nuclear Medicine, University Medical Center Mannheim, Heidelberg University, Theodor-Kutzer-Ufer 1-3, 68167 Mannheim, Germany. Electronic address:

Objectives: Coronary CT angiography (CCTA) is an excellent tool in ruling out coronary artery disease (CAD) but tends to overestimate especially highly calcified plaques. To reduce diagnostic invasive catheter angiographies (ICA), current guidelines recommend CT-FFR to determine the hemodynamic significance of coronary artery stenosis. Photon-Counting Detector CT (PCCT) revolutionized CCTA and may improve CT-FFR analysis in guiding patients.

View Article and Find Full Text PDF

[F]FDG PET/CT versus Dynamic Contrast-Enhanced CT for the diagnosis of solitary pulmonary Nodule: A Head-to-Head comparative Meta-Analysis.

Eur J Radiol

January 2025

Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Taiyuan, 030032, China; Department of Pulmonary and Critical Care Medicine, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Third Hospital of Shanxi Medical University, Tongji Shanxi Hospital, Taiyuan, 030032, China; Department of Pulmonary and Critical Care Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, 430030, China. Electronic address:

Purpose: This head-to-head comparative meta-analysis aimed to evaluate the comparative diagnostic efficacy of [F]FDG PET/CT and dynamic contrast-enhanced CT(DCE-CT) for the differentiation between malignant and benign pulmonary nodules.

Methods: An extensive search was conducted in the PubMed, Embase, and Web of Science to identify available publications up to March 23, 2024. Studies were included if they evaluated the diagnostic efficacy of [F]FDG PET/CT and DCE-CT for the characterization of pulmonary nodules.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!