A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Extending the dynamic range of electrochemical sensors using multiple modified electrodes. | LitMetric

Multiple electrodes, combined with a chemometric strategy to calibrate the measurement response, have been used for the determination of an analyte across a broader dynamic range than is possible with a single electrode. The model system used for the detection of copper comprised electrodes modified with a self-assembled monolayer. The electrodes were modified with the copper-complexing species (3-mercaptopropionic acid, thioctic acid, and the peptides cysteine and Gly-Gly-His) and copper was determined over concentrations ranging from nanomolar to millimolar using voltammetric analysis. We have demonstrated that by combining the calibration functions from the four electrodes a better estimate (i.e. with smaller variance) of the concentration of the analyte is obtained. Measurement uncertainty is expressed for independently prepared electrodes, which allows the possibility of commercial production and factory calibration. The principles of using multiple electrodes modified with recognition elements with different affinities for the target analyte to extend the dynamic range of sensors is a general one that could be applied to other analytes.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-006-1022-0DOI Listing

Publication Analysis

Top Keywords

dynamic range
12
electrodes modified
12
multiple electrodes
8
electrodes
7
extending dynamic
4
range electrochemical
4
electrochemical sensors
4
sensors multiple
4
modified
4
multiple modified
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!