Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To determine whether antemortem core needle biopsy and fine-needle aspiration of enlarged peripheral lymph nodes could be used to distinguish between inflammation and lymphosarcoma in cattle.
Design: Prospective study.
Animals: 25 cattle with enlarged peripheral lymph nodes.
Procedures: Antemortem biopsies of the selected lymph nodes were performed with an 18-gauge, 12-cm core needle biopsy instrument. Fine-needle aspirates were performed with a 20-gauge, 4-cm needle. Specimens were analyzed by pathologists who were unaware of clinical findings and final necropsy findings, and specimens were categorized as reactive, neoplastic, or nondiagnostic for comparison with necropsy results.
Results: Sensitivity and specificity of core needle biopsy ranged from 38% to 67% and from 80% to 25%, respectively. Sensitivity of fine-needle aspiration ranged from 41% to 53%, and specificity was 100%. Predictive values for positive test results ranged from 77% to 89% for core needle biopsy and were 100% for fine-needle aspiration. Predictive values for negative test results were low for both core needle biopsy and fine-needle aspiration.
Conclusions And Clinical Relevance: Results indicated that core needle biopsy and fine-needle aspiration can aid in the antemortem diagnosis of bovine enzootic lymphosarcoma. Results of fine-needle aspiration of enlarged peripheral lymph nodes were more specific and more predictive for a positive test result than were results of core needle biopsy.