Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The surface-sensitive technique of sum frequency generation (SFG) vibrational spectroscopy has been applied to study the buried interfaces between different polymers including deuterated polystyrene (d-PS) and deuterated poly(methyl methacrylate) (d-PMMA) and a two-component silane adhesion-promoting mixture (SAPM) composed of (3-glycidoxypropyl)trimethoxysilane (gamma-GPS) and a methylvinylsiloxanol (MVS). Because of the dissolution of d-PS, no SFG CH stretching signals could be collected from the d-PS/gamma-GPS interface, and SFG signals collected from the d-PS/SAPM interface gradually disappeared over time. SFG results also showed that gamma-GPS can diffuse through the d-PMMA film. The diffusion of gamma-GPS through the d-PMMA film was confirmed by SFG studies on the interface between gamma-GPS and a d-PMMA/PS two-polymer layer system. Initially the SFG signal from the PS layer was detected. However, after gamma-GPS diffused through the d-PMMA film, the PS film was dissolved by the silane, and thus the SFG signal from PS was lost. Similar experiments have been carried out at the interface between the SAPM and the d-PMMA/PS two-polymer layer system and it was found that the diffusion time of the gamma-GPS in the SAPM through the d-PMMA film was significantly longer. These results were much different to those from previous SFG studies on the analogous PET interfaces and appear consistent with differences in solubility parameters calculated for these systems.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jcis.2006.12.029 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!