Cryocooling is a technique routinely used to mitigate the effects of secondary radiation damage on macromolecules during X-ray data collection. Energy from the X-ray beam absorbed by the sample raises the temperature of the sample. How large is the temperature increase and does this reduce the effectiveness of cryocooling? Sample heating by the X-ray beam has been measured non-invasively for the first time by means of thermal imaging. Specifically, the temperature rise of 1 mm and 2 mm glass spheres (sample surrogates) exposed to an intense synchrotron X-ray beam and cooled in a laminar flow of nitrogen gas is experimentally measured. For the typical sample sizes, photon energies, fluxes, flux densities and exposure times used for macromolecular crystallographic data collection at third-generation synchrotron radiation sources and with the sample accurately centered in the cryostream, the heating by the X-ray beam is only a few degrees. This is not sufficient to raise the sample above the amorphous-ice/crystalline-ice transition temperature and, if the cryostream cools the sample to 100 K, not even enough to significantly enhance radiation damage from secondary effects.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1107/S090904950604605X | DOI Listing |
Phys Imaging Radiat Oncol
October 2024
Aarhus University Hospital, Danish Centre for Particle Therapy, Aarhus N, Denmark.
Background And Purpose: Radiotherapy for paediatric posterior fossa tumours may cause complications in the brainstem and upper spinal cord due to high doses. With proton therapy (PT) this risk may increase due to higher relative biological effectiveness (RBE) from elevated linear energy transfer (LET). This study assesses variations in LET in the brainstem and spinal cord in proton treatment plans from European centres.
View Article and Find Full Text PDFMicroscopy (Oxf)
January 2025
Department of Materials Physics, Graduate School of Engineering, Nagoya University, Chikusa-ku, Nagoya 464-8603, Japan.
The distribution of dopants in host crystals significantly influences the chemical and electronic properties of materials. Therefore, determining this distribution is crucial for optimizing material performance. The previously developed statistical ALCHEMI (St-ALCHEMI), an extension of the atom-location by channeling-enhanced microanalysis (ALCHEMI) technique, utilizes variations in electron channeling based on the beam direction relative to the crystal orientation.
View Article and Find Full Text PDFJ Oral Facial Pain Headache
September 2024
Department of Orofacial Pain and Oral Medicine, Yonsei University College of Dentistry, 03722 Seoul, Republic of Korea.
This study investigated the effects of unilateral temporomandibular joint disorders (TMJDs), specifically disc displacement without reduction and osteoarthritis on one side of the temporomandibular joint (TMJ), on facial asymmetry in women, while the contralateral TMJ exhibits normal findings. Participants were retrospectively enrolled and divided into an affected group (n = 42 with unilateral TMJD) and a control group (n = 49 with bilateral healthy TMJs). The affected group was dagnosed with osteoarthritis on cone-bema computed tomograph and anterior disk displacement without reduction on magnetic resonance imaging.
View Article and Find Full Text PDFBMJ Open
January 2025
Institute of Health Economics and Clinical Epidemiology, Faculty of Medicine and University Hospital of Cologne, Cologne, Germany
Background: Magnetic resonance-guided transurethral ultrasound ablation (MR-TULSA) is a new focal therapy for treating localised prostate cancer that is associated with fewer adverse effects (AEs) compared with established treatments. To support large-scale clinical implementation, information about cost-effectiveness is required.
Objective: To evaluate the cost-utility of MR-TULSA compared with robot-assisted radical prostatectomy (RARP), external beam radiation therapy (EBRT) and active surveillance (AS) for patients with low- to favourable intermediate-risk localised prostate cancer.
J Periodontal Res
January 2025
Department of Radiology, University of Michigan, Ann Arbor, Michigan, USA.
Aim: Ultrasonography (US) has shown accuracy in imaging healthy periodontium. This study aims to evaluate the feasibility and accuracy of US for estimating dimensions of inflamed periodontium induced by ligature and bacteria.
Methods: Periodontal tissues of maxillary as well as mandibular premolars and molars in six female mini pigs were treated with ligature and three strains of bacteria for 4-10 weeks.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!