[The significance of electrocardiogram in the estimation of correct lead position in patients with permanent ventricular pacing].

Wiad Lek

Z Kliniki Kardiologii I Katedry Kardiologii i Kardiochirurgii, Uniwersytetu Medycznego, łodzi.

Published: April 2007

Transvenous pacemaker lead malposition in the left ventricle is a rare complication of pacemaker implantation however, at the moment of diagnosis poses the serious therapeutic problem. The usual morphology for paced events originating from the right ventricle has a left bundle branch block pattern, but sometimes right bundle branch block (RBBB) configuration is identified. The report describes two cases of RBBB configuration in the electrocardiogram (ECG) after pacemaker implantation. Case 1 demonstrates a female with unintentional pacemaker lead placement in the left ventricle through patent foramen ovale. Lead malposition was diagnosed accidentally during echocardiographic study (ECHO), 6 years after implantation. Case 2 concerns a man with a RBBB pacing configuration, but with correct pacemaker lead position in the right ventricle. Authors analyze these cases in connection with other publicized reports in order to find the safe algorithm for intraoperative estimation of correct pacemaker lead location. The following algorithm of procedures during pacemaker implantation is proposed to avoid the lead malposition in the left ventricle. First, obligatory perform 12-lead ECG in pace mode during surgery or immediately after it. Second, in case of RBBB pattern in post implant ECG, make ECHO for precise lead position description.

Download full-text PDF

Source

Publication Analysis

Top Keywords

pacemaker lead
16
lead position
12
lead malposition
12
left ventricle
12
pacemaker implantation
12
estimation correct
8
lead
8
malposition left
8
bundle branch
8
branch block
8

Similar Publications

Epicardial Pacemaker Lead Related Cardiac Strangulation: The Importance of Early Recognition.

Pediatr Cardiol

January 2025

Cardiothoracic Department, Children's Health Ireland at Crumlin, Dublin, Ireland.

Lead strangulation is a dangerous complication of epicardial pacemaker insertion. This complication has been increasingly highlighted lately. Our institution has recently identified four cases over the past five years.

View Article and Find Full Text PDF

Background: Patients after transcatheter pulmonary valve implantation (TPVI) are at increased risk for infective prosthetic valve endocarditis. Diagnosis of infective endocarditis (IE) following TPVI is particularly difficult due to impaired visualization of the transcatheter pulmonary valve (TPV) with echocardiography [Delgado V, Ajmone Marsan N, de Waha S, Bonaros N, Brida M, Burri H, et al. 2023 ESC guidelines for the management of endocarditis.

View Article and Find Full Text PDF

Background: Coronary sinus (CS) lead placement in persistent left superior vena cava (PLSVC) cases is challenging because of the poor backup force of the guiding catheter within the enlarged CS. Active fixation Quadripolar leads (Attain Stability™ Quad 4798, Medtronic) can expand choice to CS branches with limited access; however, no cases of anchoring to the main body of the CS have been published to date.

Case Summary: We describe a case of cardiac resynchronization therapy pacemaker upgrade in a 79-year-old female who developed pacing-induced cardiomyopathy after pacemaker implantation via the right superior vena cava (SVC) for atrioventricular block eight years ago wherein PLSVC was revealed during the procedure.

View Article and Find Full Text PDF

Beaware of Intracardiac Potentials Induced by Intravascular Lithotripsy.

Catheter Cardiovasc Interv

January 2025

Department of Cardiology, Ageo Central General Hospital, Saitama, Japan.

Background: Intravascular lithotripsy (IVL), that generates shockwaves through spark gap discharge between emitters, has been increasingly used to treat severely calcified coronary artery lesions. However, there is a question as to whether IVL has no electrical effects on endocardial tissues or cardiac implantable devices (CIEDs).

Aims: The aim of this study was to investigate the effects of IVL-induced intracardiac potentials on cardiac electrophysiology and CIEDs.

View Article and Find Full Text PDF

A young man in his 30s presented to us with multiple episodes of syncope and exertional dyspnoea for the last 2 weeks. He was diagnosed with squamous cell carcinoma of the lower one-third of the oesophagus in 2021 for which he was treated with neoadjuvant chemoradiotherapy, followed by McKeown oesophagectomy. At 2-year follow-up, he had developed a soft tissue swelling in the scalp, which was diagnosed as a tumour recurrence and radiotherapy was initiated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!