A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An assessment of PTV margin definitions for patients undergoing conformal 3D external beam radiation therapy for prostate cancer based on an analysis of 10,327 pretreatment daily ultrasound localizations. | LitMetric

Introduction: We have assessed the planning target volume (PTV) margins required for adequate treatment of the prostate in the absence of daily localization imaging based on the statistical analysis of a large data set obtained from 5 years of use of a two-dimensional ultrasound pretreatment localization device.

Methods And Materials: Data from 387 prostate patients were analyzed retrospectively. Every patient in the study received daily pretreatment localization resulting in a total of 10,327 localizations, each comprising an isocenter displacement in three directions: anteroposterior, right-left lateral, and superior-inferior. The mean displacement for each direction for each patient was computed from daily treatment records, and a mean of the means was used in the analysis.

Results: The mean displacements required to shift the target to the required position were 6.1 mm posterior (4.4 mm SD), 2.1 mm superior (4.5 mm SD), and 0.5 mm right (3.6 mm SD). The 6.1-mm shift posterior is indicative of a systematic uncertainty. Differences in planning conditions between the computed tomography simulation and the treatment room may account for this discrepancy.

Conclusion: Our study has revealed systematic intertreatment uncertainties that would have required a nonuniform PTV margin ranging in dimensions between 2.7 mm anterior, 14.9 mm posterior, 7.7 mm right, 6.7 mm left, 11 mm superior, and 7 mm inferior to encompass the prostate for 95% of our sample if the ultrasound localization system were not used. In the absence of systematic uncertainties, a uniform PTV margin of 9 mm would suffice.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijrobp.2006.11.004DOI Listing

Publication Analysis

Top Keywords

ptv margin
12
pretreatment localization
8
assessment ptv
4
margin definitions
4
definitions patients
4
patients undergoing
4
undergoing conformal
4
conformal external
4
external beam
4
beam radiation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!