Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: The present study aimed to examine whether diastolic and systolic asynchrony exist in diastolic heart failure (DHF) and their prevalence and relationship to systolic heart failure (SHF) patients.
Background: Few data exist on mechanical asynchrony in DHF.
Methods: Tissue Doppler echocardiography was performed in 373 heart failure patients (281 with SHF and 92 with DHF) and 100 normal subjects. Diastolic and systolic asynchrony was determined by measuring the standard deviation of time to peak myocardial systolic (Ts-SD) and peak early diastolic (Te-SD) velocity using a 6-basal, 6-mid-segmental model, respectively.
Results: Both heart failure groups had prolonged Te-SD (DHF vs. SHF vs. controls subjects: 32.2 +/- 18.0 ms vs. 38.0 +/- 25.2 ms vs. 19.5 +/- 7.1 ms) and Ts-SD (31.8 +/- 17.0 ms vs. 36.7 +/- 15.2 ms vs. 17.6 +/- 7.9 ms) compared with the control group (all p < 0.001 vs. control subjects). Based on normal values, the DHF group had comparable diastolic (35.9% vs. 43.1%; chi-square = 1.48, p = NS), but less systolic asynchrony than the SHF group (39.1% vs. 56.9%; chi-square = 8.82, p = 0.003). Normal synchrony, isolated systolic, isolated diastolic, and combined asynchrony were observed in 39.1%, 25.0%, 21.7%, and 14.1% of DHF patients, respectively, and these were 25.6%, 31.3%, 17.4%, and 25.6%, correspondingly, in SHF (chi-square = 10.01, p = 0.019). The correlation between systolic and diastolic asynchrony, and between the myocardial velocities and corresponding mechanical asynchrony appeared weak. A wide QRS duration (>120 ms) was rare in DHF (10.9% vs. 37.7% in SHF) (chi-square = 16.69, p < 0.001).
Conclusions: Diastolic and/or systolic asynchrony was common in 61% of DHF patients despite narrow QRS complex. The presence of asynchrony was not related to myocardial systolic or diastolic function. Systolic and diastolic asynchrony were not tightly coupled, implying distinct mechanisms.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jacc.2006.10.022 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!